- OT1600E04K-135
ABB OT1600E04K-135 isolating switch, 4-pole, front-operated, base mounting. Rated insulation voltage 1500 V, rated impulse withstand voltage 12 kV, pollution degree 3, front IP00. Rated operational current DC-20B: 1600 A and 2500 A at 1500 V DC; AC-20B: 1600 A and 2500 A at 1000 V AC; AC-21A: 1600 A at 380–415 V, 500 V, and 690 V. Conventional free-air thermal current 1600 A and 2500 A at 40 °C; fully enclosed thermal current 1600 A and 2500 A. Rated short-time withstand current 36 kA, 50 kA, or 65 kA for 0.3 s. Power loss 48 W per pole at rated operating conditions. Standards: IEC 60947-1, -3. Mechanical durability 600 cycles. Direct-mounted pistol handle, black, 274 mm, lockable. Lug terminals, 50 mm width. Dimensions 414.5 x 372 x 148.5 mm; 22.3 kg.
- OT1600E04P
ABB OT1600E04P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 414.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600E04P-135
The ABB OT1600E04P-135 is a 4-pole front-operated switch-disconnector for base mounting, supplied with a black handle and shaft. It is rated 1500 V (Ur) with a rated insulation voltage (Ui) of 1500 V and a rated impulse withstand voltage (Uimp) of 12 kV. Conventional free-air thermal current (Ith) is 1600 A at 40 °C; conventional thermal current (Ithe) is 1600 A fully enclosed. Rated operational current AC-21A (Ie) is 1600 A at 380 to 415 V, 500 V, and 690 V. Rated short-time withstand current (Icw) is 36 kA for 0.3 s. Power loss is 48 W per pole at rated operating conditions. Mechanical durability is 600 cycles. Standards: IEC 60947-1, -3. Net dimensions: 414.5 mm width, 372 mm height, 148.5 mm depth; net weight 22.3 kg.
- OT1600E04W4P
ABB OT1600E04W4P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 594.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600E11
ABB OT1600E11 isolating switch, 2-pole, front-operated, base mounting. Rated insulation voltage 1000 V per IEC/EN 60664-1; rated operational voltage 1000 V. Conventional free-air thermal current 1600 A at 40 °C; conventional thermal current 1600 A fully enclosed. Rated operational current AC-21A: 1600 A at 380–415 V, 500 V, 690 V, and 1000 V; AC-22A: 1600 A at 380–415 V, 500 V, and 690 V; AC-23A: 1250 A at 380–415 V, 500 V, and 690 V. Rated operational power AC-23A: 710 kW at 400–415 V, 900 kW at 500 V, 1200 kW at 690 V. Rated impulse withstand voltage 12 kV; rated short-circuit making capacity 110 kA at 690 V; rated short-time withstand current 50 kA for 1 s. Standards: IEC 60947-3. Dimensions 254.5 x 372 x 167 mm; net weight 11.9 kg. Handle and shaft not included.
- OT1600E11P
The ABB OT1600E11P is a 2-pole front-operated switch-disconnector with base mounting. It is rated 1600 A conventional free-air thermal current at 40 °C and 1600 A fully enclosed. Rated operational current is 1600 A in AC-21A at 380 to 415 V, 500 V, 690 V, and 1000 V, and 1250 A in AC-23A at 380 to 415 V, 500 V, and 690 V. Rated operational power in AC-23A is 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 50 kA for 1 s. It conforms to IEC 60947-3. Dimensions are 254.5 mm wide, 372 mm high, and 167 mm deep, weighing 12.8 kg.
- OT1600E12
The ABB OT1600E12 is a 3-pole, front-operated, base-mounted switch-disconnector. It is rated for a conventional free-air thermal current (Ith) of 1600 A at an ambient temperature of 40 °C and a conventional thermal current (Ithe) of 1600 A when fully enclosed. Rated operational current is 1600 A at 380–415 V, 500 V, and 690 V for AC-21A and AC-22A, and 1250 A at the same voltages for AC-23A. Rated operational power for AC-23A is 710 kW at 400–415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. It conforms to IEC 60947-3. Dimensions are 334.5 mm wide, 372 mm high, and 167 mm deep, with a net weight of 16.8 kg. Front degree of protection is IP00. The handle and shaft are not included.
- OT1600E12C
ABB OT1600E12C is a 3-pole, front-operated isolating switch for base mounting. The conventional free-air thermal current (Ith) is 1600 A at 40 °C. Rated insulation voltage (Ui) is 1000 V and rated impulse withstand voltage (Uimp) is 12 kV. Line terminals can be configured top in - bottom out or bottom in - top out. Power loss is 48 W per pole at rated operating conditions. The front degree of protection is IP20, with pollution degree 3. Dimensions are 400 mm width, 372 mm height, and 309 mm depth; net weight is 37.37 kg. The handle is black; handle and shaft are not included. Manufacturer ID: 1SCA103292R1001.