- OT1600E11P
The ABB OT1600E11P is a 2-pole front-operated switch-disconnector with base mounting. It is rated 1600 A conventional free-air thermal current at 40 °C and 1600 A fully enclosed. Rated operational current is 1600 A in AC-21A at 380 to 415 V, 500 V, 690 V, and 1000 V, and 1250 A in AC-23A at 380 to 415 V, 500 V, and 690 V. Rated operational power in AC-23A is 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 50 kA for 1 s. It conforms to IEC 60947-3. Dimensions are 254.5 mm wide, 372 mm high, and 167 mm deep, weighing 12.8 kg.
- OT1600E12
The ABB OT1600E12 is a 3-pole, front-operated, base-mounted switch-disconnector. It is rated for a conventional free-air thermal current (Ith) of 1600 A at an ambient temperature of 40 °C and a conventional thermal current (Ithe) of 1600 A when fully enclosed. Rated operational current is 1600 A at 380–415 V, 500 V, and 690 V for AC-21A and AC-22A, and 1250 A at the same voltages for AC-23A. Rated operational power for AC-23A is 710 kW at 400–415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. It conforms to IEC 60947-3. Dimensions are 334.5 mm wide, 372 mm high, and 167 mm deep, with a net weight of 16.8 kg. Front degree of protection is IP00. The handle and shaft are not included.
- OT1600E12C
ABB OT1600E12C is a 3-pole, front-operated isolating switch for base mounting. The conventional free-air thermal current (Ith) is 1600 A at 40 °C. Rated insulation voltage (Ui) is 1000 V and rated impulse withstand voltage (Uimp) is 12 kV. Line terminals can be configured top in - bottom out or bottom in - top out. Power loss is 48 W per pole at rated operating conditions. The front degree of protection is IP20, with pollution degree 3. Dimensions are 400 mm width, 372 mm height, and 309 mm depth; net weight is 37.37 kg. The handle is black; handle and shaft are not included. Manufacturer ID: 1SCA103292R1001.
- OT1600E12CK
ABB OT1600E12CK is a 3-pole isolating switch (switch-disconnector) with a front-operated mechanism. The manufacturer ID is 1SCA117998R1001. The device is rated for a thermal current of 1600 A in conventional free-air conditions and 1600 A fully enclosed. It is suitable for voltage ratings of 380–415 V, 500 V, and 690 V. A terminal bolt kit is included. The switch-disconnector is compliant with IEC 60947-3.
- OT1600E12CP
The ABB OT1600E12CP is a 3-pole, front-operated isolating switch for base mounting, with screw terminals and a black handle and shaft included. It is rated 1600 A at 40 °C conventional free-air thermal current (Ith), with rated insulation voltage (Ui) 1000 V and rated impulse withstand voltage (Uimp) 12 kV. Rated operational current is 1600 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated short-time withstand current (Icw) is 50 kA rms for 1 s. Front degree of protection is IP20; pollution degree 3. Tightening torque is 50 to 75 N·m according to IEC 60947-1.
- OT1600E12DDP
The ABB OT1600E12DDP is a 6-pole isolating switch with a manufacturer ID of 1SCA130997R1001. It is rated for a conventional thermal current of 1600 A fully enclosed and a rated operational voltage of 1000 V in the main circuit. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Rated short-time withstand current is 50 kA for 1 s. The switch meets IEC 60947-3, has front IP00 protection, pollution degree 3, and lug terminals with tightening torque of 50 to 75 N·m according to IEC 60947-1. It measures 400 mm wide, 372 mm high, and 309 mm deep, weighs 47.9 kg, and includes a black handle and shaft.
- OT1600E12P
ABB OT1600E12P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 334.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600E12W4P
ABB OT1600E12W4P isolating switch, 3-pole, front-operated, base mounting. Rated insulation voltage 1000 V per IEC/EN 60664-1; rated impulse withstand voltage 12 kV; rated operational voltage 1000 V main circuit. Conventional free-air thermal current 1600 A at 40 °C; conventional thermal current fully enclosed 1600 A. Rated operational current AC-21A and AC-22A: 1600 A at 380 to 415 V, 500 V, and 690 V. AC-23A: 1250 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A: 710 kW at 400 to 415 V, 900 kW at 500 V, 1200 kW at 690 V. Rated short-time withstand current 50 kA for 1 s; rated short-circuit making capacity 110 kA at 690 V. Lug terminals, tightening torque 50 to 75 N·m per IEC 60947-1. Front IP00; pollution degree 3. Dimensions 454.5 x 372 x 167 mm; 16.5 kg. Standards: IEC 60947-3.