- OT1600E12DDP
The ABB OT1600E12DDP is a 6-pole isolating switch with a manufacturer ID of 1SCA130997R1001. It is rated for a conventional thermal current of 1600 A fully enclosed and a rated operational voltage of 1000 V in the main circuit. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Rated short-time withstand current is 50 kA for 1 s. The switch meets IEC 60947-3, has front IP00 protection, pollution degree 3, and lug terminals with tightening torque of 50 to 75 N·m according to IEC 60947-1. It measures 400 mm wide, 372 mm high, and 309 mm deep, weighs 47.9 kg, and includes a black handle and shaft.
- OT1600E12P
ABB OT1600E12P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 334.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600E12W4P
ABB OT1600E12W4P isolating switch, 3-pole, front-operated, base mounting. Rated insulation voltage 1000 V per IEC/EN 60664-1; rated impulse withstand voltage 12 kV; rated operational voltage 1000 V main circuit. Conventional free-air thermal current 1600 A at 40 °C; conventional thermal current fully enclosed 1600 A. Rated operational current AC-21A and AC-22A: 1600 A at 380 to 415 V, 500 V, and 690 V. AC-23A: 1250 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A: 710 kW at 400 to 415 V, 900 kW at 500 V, 1200 kW at 690 V. Rated short-time withstand current 50 kA for 1 s; rated short-circuit making capacity 110 kA at 690 V. Lug terminals, tightening torque 50 to 75 N·m per IEC 60947-1. Front IP00; pollution degree 3. Dimensions 454.5 x 372 x 167 mm; 16.5 kg. Standards: IEC 60947-3.
- OT1600E12W8P
The ABB OT1600E12W8P is a 3-pole front-operated switch-disconnector with base mounting. Conventional free-air thermal current is 1600 A at 40 °C; conventional thermal current fully enclosed is 1600 A. Rated operational current AC-21A and AC-22A is 1600 A at 380 to 415 V, 500 V, and 690 V; AC-23A is 1250 A at those voltages. Rated operational power AC-23A is 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 50 kA for 1 s. Rated short-circuit making capacity is 110 kA at 690 V. Standards: IEC 60947-3. Dimensions are 594.5 mm wide, 372 mm high, and 167 mm deep; net weight is 20.5 kg.
- OT1600E13CK
ABB OT1600E13CK is an isolating switch identified by manufacturer ID 1SCA118001R1001. It is intended for power transfer switching applications. The switch uses components selected for consistent operation and is configured to support transitions between power sources. No electrical ratings, mechanical specifications, or standards are stated for this model.
- OT1600E13CP
The ABB OT1600E13CP is a 4-pole, front-operated isolating switch for base mounting, with a 1600 A ampere rating. Conventional free-air thermal current Ith is 1600 A at 40 °C. Rated insulation voltage Ui is 1000 V and rated impulse withstand voltage Uimp is 12 kV. Rated operational current is 1600 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated short-time withstand current Icw is 50 kA rms for 1 s. Power loss is 48 W per pole at rated operating conditions. Dimensions are 480 mm width, 372 mm height, and 309 mm depth; net weight is 47.66 kg. Front degree of protection is IP20, pollution degree 3, screw terminals, tightening torque 50 to 75 N·m according to IEC 60947-1.
- OT1600E13P
The ABB OT1600E13P is a four-pole front-operated switch-disconnector, base mounting, with the operating mechanism located between the poles. It is rated 1600 A conventional free-air thermal current at 40 °C and 1600 A fully enclosed conventional thermal current. Rated operational current is 1600 A at 380 to 415 V, 500 V, and 690 V for AC-21A and AC-22A, and 1250 A at the same voltages for AC-23A. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 50 kA for 1 s. The fourth pole is on the right side, switched with simultaneous function. Terminals are lug type, tightening torque 50 to 75 N·m according to IEC 60947-1. Standards: IEC 60947-3. Front degree of protection: IP00.
- OT1600E22
The ABB OT1600E22 is a front-operated, non-fusible switch-disconnector with four poles and a 1600 A rating. Conventional free-air thermal current (Ith) is 1600 A at 40 °C; conventional thermal current (Ithe) is 1600 A fully enclosed. The fourth pole is on the right side and is switched with a simultaneous function. Mechanical durability is 6000 operations. The device mounts on a base and has front protection of IP00 and pollution degree 3. Dimensions are 414.5 mm wide, 372 mm high, and 167 mm deep; net weight is 21.6 kg. The handle and shaft are not included. Manufacturer ID: 1SCA101545R1001.