- E213-25-002
ABB E213-25-002 is a control protection switch with manufacturer ID 2CCA703046R0001. It is a 2-pole changeover switch with two CO contacts and two auxiliary CO (SPDT) contacts, using double interrupting contacts. Rated current is 25 A at 50/60 Hz, with rated voltage minimum 250 V and rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508. Power loss is 0.8 W. Copper conductors connect with 1.2-1.5 N·m tightening torque; connecting capacity is solid 1x1–6 mm², solid 2x2.5 mm², flexible 1x0.75–2x2.5 mm². Ambient air temperature is -25 to +55 °C in operation and -40 to +70 °C in storage. Grey cover and control element. Sealable in On and Off positions.
- E214-16-101
The ABB E214-16-101 is a single-pole control protection switch with a rated current of 16 A and a rated operational voltage of 250 V AC according to EN, or 240 V AC according to UL 508. It uses double interrupting contacts and provides one CO contact and one auxiliary CO (SPDT) contact. Rated frequency is 50/60 Hz, rated service short-circuit breaking capacity is 3 kA, and power loss is 0.32 W. Connecting capacity covers solid conductors 1x1 to 6 mm² and 2x2.5 mm², and flexible conductors 1x0.75 to 2x2.5 mm², with copper conductor material and tightening torque 1.2 to 1.5 N·m. The switch is sealable in the On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508.
- E214-16-202
ABB E214-16-202 is a two-pole control protection switch with two CO (SPDT) auxiliary contacts and double interrupting contacts. It is rated 16 A at a minimum 250 V, with rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508, at 50/60 Hz. Rated service short-circuit breaking capacity is 3 kA, and power loss is 0.82 W. Connecting capacity is solid 1x1 to 6 mm², solid 2x2.5 mm², and flexible 1x0.75 to 2x2.5 mm², with copper conductors and tightening torque 1.2 to 1.5 N·m. The switch is sealable in the On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508. Grey cover and control element.
- E214-25-101
ABB E214-25-101 is a control protection switch with manufacturer ID 2CCA703026R0001. It is a 1-pole device with one CO main contact and one CO (SPDT) auxiliary contact, using double interrupting contacts. Rated current is 25 A at 50/60 Hz. Rated operational voltage is 250 V AC according to EN and 240 V AC according to UL 508; rated voltage (Ur) is minimum 250 V, AC input. Rated service short-circuit breaking capacity (Ics) is 3 kA, and power loss is 0.4 W. Conductors are copper, with connecting capacity for solid 1x1 to 6 mm², solid 2x2.5 mm², and flexible 1x0.75 to 2x2.5 mm². Tightening torque is 1.2 to 1.5 N·m. The switch is sealable in the On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508. Cover and control element are grey.
- E214-25-202
ABB E214-25-202 control protection switch, 2-pole, with double interrupting contacts. Rated current 25 A, rated voltage minimum 250 V, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, rated frequency 50/60 Hz, rated service short-circuit breaking capacity 3 kA. Two CO contacts and two auxiliary CO (SPDT) contacts; no main NO or NC contacts. Copper conductors, connecting capacity solid 1x1-6 mm² or 2x2.5 mm², flexible 1x0.75-2x2.5 mm²; tightening torque 1.2-1.5 N·m. Power loss 0.88 W. Dimensions 18 mm wide, 85 mm high, 68 mm deep; 87 g. IP20; operation -25 to +55 °C, storage -40 to +70 °C. Sealable in On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508.
- E215-16-11B
ABB E215-16-11B control protection switch, manufacturer ID 2CCA703150R0001. Rated current 16 A at 50/60 Hz, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, maximum switching voltage 250 V. Two poles with double interrupting contacts, one normally open and one normally closed main contact. Power loss 0.5 W; power watt 0.72 W. Lamp rated voltage 48 to 48 V. Tightening torque 1.2-1.5 N·m; copper conductors. Grey housing and control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11C
ABB E215-16-11C control protection switch, manufacturer ID 2CCA703151R0001. Rated current 16 A at 50/60 Hz, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, maximum switching voltage 250 V. Contact configuration: 1 NO and 1 NC, 2 poles, double interrupting contacts. Power loss 0.5 W; power watt 0.72 W. Rated voltage for lamp 48 V. Copper conductors, tightening torque 1.2-1.5 N·m. Red control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11D
ABB E215-16-11D control protection switch, manufacturer ID 2CCA703152R0001. Rated current 16 A at rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508, with rated frequency 50/60 Hz and maximum switching voltage 250 V. Contact configuration is 1 NO plus 1 NC, 2 poles, double interrupting contacts. Lamp rated voltage 48 V. Power loss 0.5 W; power 0.72 W. Terminal tightening torque 1.2 to 1.5 N·m; conductor material copper. Green control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.