- E214-16-101
The ABB E214-16-101 is a single-pole control protection switch with a rated current of 16 A and a rated operational voltage of 250 V AC according to EN, or 240 V AC according to UL 508. It uses double interrupting contacts and provides one CO contact and one auxiliary CO (SPDT) contact. Rated frequency is 50/60 Hz, rated service short-circuit breaking capacity is 3 kA, and power loss is 0.32 W. Connecting capacity covers solid conductors 1x1 to 6 mm² and 2x2.5 mm², and flexible conductors 1x0.75 to 2x2.5 mm², with copper conductor material and tightening torque 1.2 to 1.5 N·m. The switch is sealable in the On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508.
- E214-16-202
ABB E214-16-202 is a two-pole control protection switch with two CO (SPDT) auxiliary contacts and double interrupting contacts. It is rated 16 A at a minimum 250 V, with rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508, at 50/60 Hz. Rated service short-circuit breaking capacity is 3 kA, and power loss is 0.82 W. Connecting capacity is solid 1x1 to 6 mm², solid 2x2.5 mm², and flexible 1x0.75 to 2x2.5 mm², with copper conductors and tightening torque 1.2 to 1.5 N·m. The switch is sealable in the On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508. Grey cover and control element.
- E214-25-101
ABB E214-25-101 is a control protection switch with manufacturer ID 2CCA703026R0001. It is a 1-pole device with one CO main contact and one CO (SPDT) auxiliary contact, using double interrupting contacts. Rated current is 25 A at 50/60 Hz. Rated operational voltage is 250 V AC according to EN and 240 V AC according to UL 508; rated voltage (Ur) is minimum 250 V, AC input. Rated service short-circuit breaking capacity (Ics) is 3 kA, and power loss is 0.4 W. Conductors are copper, with connecting capacity for solid 1x1 to 6 mm², solid 2x2.5 mm², and flexible 1x0.75 to 2x2.5 mm². Tightening torque is 1.2 to 1.5 N·m. The switch is sealable in the On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508. Cover and control element are grey.
- E214-25-202
ABB E214-25-202 control protection switch, 2-pole, with double interrupting contacts. Rated current 25 A, rated voltage minimum 250 V, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, rated frequency 50/60 Hz, rated service short-circuit breaking capacity 3 kA. Two CO contacts and two auxiliary CO (SPDT) contacts; no main NO or NC contacts. Copper conductors, connecting capacity solid 1x1-6 mm² or 2x2.5 mm², flexible 1x0.75-2x2.5 mm²; tightening torque 1.2-1.5 N·m. Power loss 0.88 W. Dimensions 18 mm wide, 85 mm high, 68 mm deep; 87 g. IP20; operation -25 to +55 °C, storage -40 to +70 °C. Sealable in On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508.
- E215-16-11B
ABB E215-16-11B control protection switch, manufacturer ID 2CCA703150R0001. Rated current 16 A at 50/60 Hz, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, maximum switching voltage 250 V. Two poles with double interrupting contacts, one normally open and one normally closed main contact. Power loss 0.5 W; power watt 0.72 W. Lamp rated voltage 48 to 48 V. Tightening torque 1.2-1.5 N·m; copper conductors. Grey housing and control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11C
ABB E215-16-11C control protection switch, manufacturer ID 2CCA703151R0001. Rated current 16 A at 50/60 Hz, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, maximum switching voltage 250 V. Contact configuration: 1 NO and 1 NC, 2 poles, double interrupting contacts. Power loss 0.5 W; power watt 0.72 W. Rated voltage for lamp 48 V. Copper conductors, tightening torque 1.2-1.5 N·m. Red control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11D
ABB E215-16-11D control protection switch, manufacturer ID 2CCA703152R0001. Rated current 16 A at rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508, with rated frequency 50/60 Hz and maximum switching voltage 250 V. Contact configuration is 1 NO plus 1 NC, 2 poles, double interrupting contacts. Lamp rated voltage 48 V. Power loss 0.5 W; power 0.72 W. Terminal tightening torque 1.2 to 1.5 N·m; conductor material copper. Green control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11E
The ABB E215-16-11E is a two-pole control protection switch with one normally open and one normally closed main contact, using double interrupting contacts. It is rated 16 A at 50/60 Hz, with an operational voltage of 250 V AC according to EN and 240 V AC according to UL 508, and a maximum switching voltage of 250 V. The lamp rating is 48 to 48 V. Power loss is 0.5 W and power watt is 0.72 W. The conductor material is copper, tightening torque is 1.2 to 1.5 N·m, and the control element is yellow. It can be sealed in the on and off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.