- E214-25-202
ABB E214-25-202 control protection switch, 2-pole, with double interrupting contacts. Rated current 25 A, rated voltage minimum 250 V, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, rated frequency 50/60 Hz, rated service short-circuit breaking capacity 3 kA. Two CO contacts and two auxiliary CO (SPDT) contacts; no main NO or NC contacts. Copper conductors, connecting capacity solid 1x1-6 mm² or 2x2.5 mm², flexible 1x0.75-2x2.5 mm²; tightening torque 1.2-1.5 N·m. Power loss 0.88 W. Dimensions 18 mm wide, 85 mm high, 68 mm deep; 87 g. IP20; operation -25 to +55 °C, storage -40 to +70 °C. Sealable in On and Off positions. Standards: EN60669-1, VDE0632-1, IEC60068-2-2, IEC60068-2-1, IEC60068-2-38, UL508.
- E215-16-11B
ABB E215-16-11B control protection switch, manufacturer ID 2CCA703150R0001. Rated current 16 A at 50/60 Hz, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, maximum switching voltage 250 V. Two poles with double interrupting contacts, one normally open and one normally closed main contact. Power loss 0.5 W; power watt 0.72 W. Lamp rated voltage 48 to 48 V. Tightening torque 1.2-1.5 N·m; copper conductors. Grey housing and control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11C
ABB E215-16-11C control protection switch, manufacturer ID 2CCA703151R0001. Rated current 16 A at 50/60 Hz, rated operational voltage 250 V AC per EN and 240 V AC per UL 508, maximum switching voltage 250 V. Contact configuration: 1 NO and 1 NC, 2 poles, double interrupting contacts. Power loss 0.5 W; power watt 0.72 W. Rated voltage for lamp 48 V. Copper conductors, tightening torque 1.2-1.5 N·m. Red control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11D
ABB E215-16-11D control protection switch, manufacturer ID 2CCA703152R0001. Rated current 16 A at rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508, with rated frequency 50/60 Hz and maximum switching voltage 250 V. Contact configuration is 1 NO plus 1 NC, 2 poles, double interrupting contacts. Lamp rated voltage 48 V. Power loss 0.5 W; power 0.72 W. Terminal tightening torque 1.2 to 1.5 N·m; conductor material copper. Green control element. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11E
The ABB E215-16-11E is a two-pole control protection switch with one normally open and one normally closed main contact, using double interrupting contacts. It is rated 16 A at 50/60 Hz, with an operational voltage of 250 V AC according to EN and 240 V AC according to UL 508, and a maximum switching voltage of 250 V. The lamp rating is 48 to 48 V. Power loss is 0.5 W and power watt is 0.72 W. The conductor material is copper, tightening torque is 1.2 to 1.5 N·m, and the control element is yellow. It can be sealed in the on and off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11F
ABB E215-16-11F control protection switch, manufacturer ID 2CCA703154R0001. Rated current 16 A at 50/60 Hz; rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508; maximum switching voltage 250 V. Lamp rated voltage 48 V. Configuration: 2 poles, one NO and one NC main contact, double interrupting contacts, copper conductors. Power loss 0.5 W; power 0.72 W. Tightening torque 1.2 to 1.5 N·m. Black control element and enclosure. Sealable in the On and Off positions. Standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508.
- E215-16-11G
ABB E215-16-11G control protection switch with 1 NC and 1 NO main contact, double interrupting contacts, and two poles. Rated current is 16 A at 50/60 Hz, with rated operational voltage 250 V AC according to EN and 240 V AC according to UL 508; maximum switching voltage is 250 V. Power loss is 0.5 W. Connections accept copper conductors, solid 1x1 to 6 mm² or 2x2.5 mm², flexible 1x0.75 to 2x2.5 mm², with tightening torque 1.2 to 1.5 N·m. Dimensions are 9 mm wide, 85 mm high, 68 mm deep, 49 g. IP20, ambient operation -25 to +55 °C. Standards include EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, and UL508.
- E217-16-01B
ABB E217-16-01B is a control protection switch with one normally closed (NC) main contact and a white LED indicator. It is rated 16 A at 50/60 Hz, with a lamp rated voltage of 230 to 250 V and an AC voltage range of 115 to 250 V. Rated operational voltage is 250 V AC according to EN and 240 V AC according to UL 508. Maximum switching voltage is 250 V, power loss is 1.1 W, and tightening torque is 1.2 to 1.5 N·m. The switch uses double interrupting contacts with copper conductors and can be sealed in the On and Off positions. Referenced standards: EN60068-2-1, EN60068-2-2, EN60068-2-30, DIN EN 60669-1, VDE 0632-1, UL508. Manufacturer ID: 2CCA703250R0001.