- AFS146-30-12-12
ABB AFS146-30-12-12 AC contactor, manufacturer ID 1SFL467081R1212. Three main contacts NO, zero NC; auxiliary contacts: one NO and two NC. Main circuit rated operational voltage 1000 V at 50/60 Hz. Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, 40 °C: 225 A. Rated operational current AC-3: 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, 60 A at 1000 V, all at 60 °C. Rated operational power AC-3: 75 kW at 415 V, 90 kW at 440 V, 500 V, and 690 V, 75 kW at 1000 V. Dimensions: 90 mm width, 126 mm depth/length, 150 mm height; net weight 1.3 kg.
- AFS146-30-12-14
The ABB AFS146-30-12-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, each at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg. Manufacturer ID: 1SFL467081R1412.
- AFS146-30-12-33
The ABB AFS146-30-12-33 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. Its main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AFS146-30-12-34
ABB AFS146-30-12-34 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.3 kg.
- AFS146-30-12B-11
ABB AFS146-30-12B-11 AC contactor, manufacturer ID 1SFL467082R1112. It has three main contacts (NO) and no main NC contacts, plus one auxiliary NO and two auxiliary NC contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 225 A at 40 °C, 200 A at 60 °C, and 175 A at 70 °C at both 1000 V and 690 V. AC-3 rated operational current is 146 A at 415 V, 440 V, and 380/400 V at 60 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.3 kg.
- AFS146-30-12B-12
ABB AFS146-30-12B-12 is a three-pole AC contactor with one normally open and two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V, 500 V, and 690 V, and 75 kW at 1000 V. Manufacturer ID: 1SFL467082R1212.
- AFS146-30-12B-13
The ABB AFS146-30-12B-13 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. Its main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 60 °C, 130 A at 500 V and 60 °C, 93 A at 690 V and 60 °C, and 60 A at 1000 V and 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AFS146-30-12B-14
The ABB AFS146-30-12B-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; weight is 1.3 kg. Manufacturer ID: 1SFL467082R1412.