- AFS146-30-12-34
ABB AFS146-30-12-34 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.3 kg.
- AFS146-30-12B-11
ABB AFS146-30-12B-11 AC contactor, manufacturer ID 1SFL467082R1112. It has three main contacts (NO) and no main NC contacts, plus one auxiliary NO and two auxiliary NC contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 225 A at 40 °C, 200 A at 60 °C, and 175 A at 70 °C at both 1000 V and 690 V. AC-3 rated operational current is 146 A at 415 V, 440 V, and 380/400 V at 60 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.3 kg.
- AFS146-30-12B-12
ABB AFS146-30-12B-12 is a three-pole AC contactor with one normally open and two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V, 500 V, and 690 V, and 75 kW at 1000 V. Manufacturer ID: 1SFL467082R1212.
- AFS146-30-12B-13
The ABB AFS146-30-12B-13 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. Its main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 60 °C, 130 A at 500 V and 60 °C, 93 A at 690 V and 60 °C, and 60 A at 1000 V and 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AFS146-30-12B-14
The ABB AFS146-30-12B-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; weight is 1.3 kg. Manufacturer ID: 1SFL467082R1412.
- AFS146-30-12B-34
The ABB AFS146-30-12B-34 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V.
- AFS16-30-22-11
The ABB AFS16-30-22-11 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 and 16 A per IEC 60947-5-1, both at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 10.5 A at 690 V, both at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL177082R1122.
- AFS16-30-22-13
The ABB AFS16-30-22-13 is a 3-pole AC contactor with 3 NO main contacts and 2 NO plus 2 NC auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.