- AFS146-30-12B-14
The ABB AFS146-30-12B-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; weight is 1.3 kg. Manufacturer ID: 1SFL467082R1412.
- AFS146-30-12B-34
The ABB AFS146-30-12B-34 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V.
- AFS16-30-22-11
The ABB AFS16-30-22-11 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 and 16 A per IEC 60947-5-1, both at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 10.5 A at 690 V, both at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL177082R1122.
- AFS16-30-22-13
The ABB AFS16-30-22-13 is a 3-pole AC contactor with 3 NO main contacts and 2 NO plus 2 NC auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFS16Z-30-22-30
The ABB AFS16Z-30-22-30 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 130.5 mm deep, and 86 mm high, and weighs 0.49 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 18 A at 415 V and 60 °C, and 10.5 A at 690 V and 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFS190-30-12-11
The ABB AFS190-30-12-11 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 440 V, 135 A at 500 V and 690 V, and 85 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 90 kW at 500 V, 132 kW at 690 V, and 110 kW at 1000 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AFS190-30-12-12
The ABB AFS190-30-12-12 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. Its main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 440 V, 135 A at 500 V and 690 V, and 85 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 90 kW at 500 V, 132 kW at 690 V, and 110 kW at 1000 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg. Manufacturer ID: 1SFL487082R1212.
- AFS190-30-12-13
The ABB AFS190-30-12-13 is an AC contactor with three normally open main contacts and auxiliary contacts consisting of one normally open and two normally closed. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and an insulation rating of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V according to UL/CSA. Conventional free-air thermal current is 275 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 190 A at 415 V and 60 °C, with rated operational power of 90 kW at 415 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg. Mechanical durability is 5 million operating cycles.