- AFS190-30-12-12
The ABB AFS190-30-12-12 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. Its main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 440 V, 135 A at 500 V and 690 V, and 85 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 90 kW at 500 V, 132 kW at 690 V, and 110 kW at 1000 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg. Manufacturer ID: 1SFL487082R1212.
- AFS190-30-12-13
The ABB AFS190-30-12-13 is an AC contactor with three normally open main contacts and auxiliary contacts consisting of one normally open and two normally closed. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and an insulation rating of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), or 600 V according to UL/CSA. Conventional free-air thermal current is 275 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 190 A at 415 V and 60 °C, with rated operational power of 90 kW at 415 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg. Mechanical durability is 5 million operating cycles.
- AFS190-30-12-14
The ABB AFS190-30-12-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 440 V, 135 A at 500 V and 690 V, and 85 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 90 kW at 500 V, 132 kW at 690 V, and 110 kW at 1000 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AFS190-30-12-33
The ABB AFS190-30-12-33 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 at 60 °C is 190 A at 415 V, 440 V, and 380/400 V, 135 A at 500 V and 690 V, and 85 A at 1000 V. Rated operational power AC-3 at 60 °C is 90 kW at 415 V and 380/400 V, 110 kW at 440 V and 1000 V, and 132 kW at 690 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg.
- AFS190-30-12-34
The ABB AFS190-30-12-34 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It measures 105 mm wide, 152 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 275 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 190 A at 415 V and 440 V, 135 A at 500 V and 690 V, and 85 A at 1000 V, each at 60 °C. Rated operational power AC-3 is 90 kW at 415 V, 110 kW at 440 V, 90 kW at 500 V, 132 kW at 690 V, and 110 kW at 1000 V.
- AFS205-30-12-12
The ABB AFS205-30-12-12 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It measures 105 mm wide, 152 mm deep, and 196 mm high, and weighs 2.4 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 60 °C, and rated operational power AC-3 is 110 kW at 415 V. Short-circuit protection uses gG type fuses rated 400 A. The manufacturer ID is 1SFL527082R1212.
- AFS205-30-12-13
The ABB AFS205-30-12-13 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 110 kW at 415 V and 132 kW at 440 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high; net weight is 2.4 kg. Short-circuit protection uses gG type fuses rated 400 A.
- AFS205-30-12-14
The ABB AFS205-30-12-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It includes one normally open and two normally closed auxiliary contacts. The main circuit is rated for 1000 V at 50/60 Hz. Conventional free-air thermal current is 350 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 205 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 110 kW at 415 V and 380/400 V, and 132 kW at 440 V and 1000 V. Dimensions are 105 mm wide, 152 mm deep, and 196 mm high, with a net weight of 2.4 kg.