- AF305-40-00-14
The ABB AF305-40-00-14 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 375 A at 1000 V and 40 °C, 325 A at 1000 V and 60 °C, and 260 A at 1000 V and 70 °C. AC-3 ratings include 305 A at 415 V and 55 °C, with rated operational power AC-3 of 160 kW at 415 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF305-40-11-11
The ABB AF305-40-11-11 is a 4-pole AC contactor with four NO main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V at 50 Hz, with AC-3 rated operational current of 305 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C, and AC-3 rated operational power of 160 kW at 380/400 V, 415 V, and 440 V, and 90 kW at 220/230/240 V. The rated control circuit voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 184 mm wide, 180 mm deep, and 225.4 mm high, with a net weight of 5.7 kg. The manufacturer ID is 1SFL587102R1111.
- AF305-40-11-12
ABB AF305-40-11-12 AC contactor, manufacturer ID 1SFL587102R1211. Four main contacts NO and no main contacts NC; one auxiliary contact NO and one NC. Main circuit rated operational voltage 1000 V at 50 Hz. Rated operational current AC-3 is 305 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 380/400 V, 415 V, and 440 V, and 90 kW at 220/230/240 V. Rated control circuit voltage is 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Dimensions are 184 mm wide, 180 mm deep, and 225.4 mm high; net weight 5.7 kg. Main circuit terminals are bars.
- AF305-40-11-13
ABB AF305-40-11-13 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 50 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 305 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 55 °C, corresponding to 160 kW at 380/400 V, 415 V, and 440 V, and 90 kW at 220/230/240 V. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 184 mm wide, 180 mm deep, and 225.4 mm high; weight is 5.7 kg.
- AF305-40-11-14
The ABB AF305-40-11-14 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 60 Hz. Rated operational current AC-3 is 305 A at 415 V, 440 V, and 380/400 V, each at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Conventional free-air thermal current is 500 A per IEC 60947-4-1 at 40 °C. Dimensions are 184 mm width, 180 mm depth, and 225.4 mm height; net weight 5.7 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF305-40-22-11
The ABB AF305-40-22-11 is a four-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 380/400 V, 415 V, and 440 V, and 90 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF305-40-22-12
ABB AF305-40-22-12 AC contactor, manufacturer ID 1SFL587102R1222. Four main contacts NO, zero NC, plus two auxiliary contacts NO and two NC. Main circuit rated operational voltage 1000 V, rated frequency 60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors, 40 °C: 500 A. Rated operational current AC-1: 500 A at 690 V, 40 °C; 375 A at 1000 V, 40 °C. Rated operational power AC-3: 160 kW at 380/400 V, 415 V, and 440 V; 90 kW at 220/230/240 V. Rated insulation voltage per IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V; per UL/CSA 600 V. Rated impulse withstand voltage 8 kV. Short-circuit protective devices: gG type fuses 630 A. Main circuit terminals: bars. Dimensions 184 mm width, 180 mm depth, 225 mm height; net weight 5.7 kg.
- AF305-40-22-13
The ABB AF305-40-22-13 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It includes two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.