Industrial Automation Parts. Prompt replies from real people.

ABB AF305-40-11-13 4-Pole 1000V IEC/600V UL Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB AF305-40-11-13?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF305-40-11-13 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF305-40-11-13
Material Number
1SFL587102R1311
Manufacturer
ABB
Product ID
75766

Get a Free Quote

Request pricing and availability for AF305-40-11-13.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
5.7 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 Hz
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A (1000 V) 60 °C 325 A (1000 V) 70 °C 260 A (690 V) 40 °C 500 A (690 V) 60 °C 400 A (690 V) 70 °C 325 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW (440 V) 160 kW (380 / 400 V) 160 kW (220 / 230 / 240 V) 90 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
See all specifications

Product Highlights

  1. Main Contacts: 4 normally open (NO) main contacts with no normally closed (NC) main contacts
  2. Auxiliary Contacts: 1 normally open (NO) and 1 normally closed (NC) auxiliary contact
  3. Rated Operational Voltage: 1000 V for the main circuit, with rated insulation voltage of 1000 V per IEC 60947-4-1 and 600 V per UL/CSA
  4. Motor Switching Capacity: AC-3 rated operational power of 160 kW at 380 to 440 V and 90 kW at 220 to 240 V, with AC-3 making capacity of 10 x Ie and breaking capacity of 8 x Ie
  5. Coil Control: Rated control circuit voltage of 100 to 250 V at 50 Hz, 60 Hz, or DC, with an operating range of 0.85 to 1.1 x Uc at ambient temperatures up to 70 °C
  6. Current Ratings: Conventional free-air thermal current of 500 A and AC-1 rated operational current of 500 A at 690 V and 40 °C, 375 A at 1000 V and 40 °C, and 260 A at 1000 V and 70 °C
  7. Short-Circuit Protection: gG type fuses rated 630 A, with rated short-time withstand current (Icw) of 3050 A for 1 s and 2440 A for 10 s at 40 °C in free air
  8. Mechanical Durability: 5 million operating cycles with a maximum mechanical switching frequency of 300 cycles per hour
  9. Terminal and Connection Data: Main circuit bars accept rigid copper cables from 6 to 300 mm², rigid aluminum cables from 185 to 240 mm², or flexible cables from 2 x 70 to 185 mm², auxiliary circuit accepts 2 x 0.75 to 2.5 mm² flexible or 2 x 1 to 4 mm² solid or stranded conductors
  10. Operating Conditions: Ambient air temperature range of -40 to 70 °C without a thermal overload relay and -25 to 50 °C with one, maximum operating altitude of 3000 m without derating, and main terminal protection of IP00 with coil terminals rated IP20
  11. Dimensions and Weight: 184 mm wide, 180 mm deep, 225.4 mm high, and 5.7 kg net weight
AF305-40-11-13

Product Information

Technical Specifications

Specifications for AF305-40-11-13

ParameterValue
Product Net Width184 mm
Product Net Depth / Length180 mm
Product Net Height225.4 mm
Product Net Weight5.7 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 375 A (1000 V) 60 °C 325 A (1000 V) 70 °C 260 A (690 V) 40 °C 500 A (690 V) 60 °C 400 A (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 305 A (440 V) 55 °C 305 A (380400 V) 55 °C 305 A (220230240 V) 55 °C 305 A
Rated Operational Power AC-3 (Pe)(415 V) 160 kW (440 V) 160 kW (380400 V) 160 kW (220230240 V) 90 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
ParameterValue
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A Holding at Max. Rated Control Circuit Voltage DC 4.5 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Operate TimeBetween Coil De-energization and NO Contact Opening 45 ... 80 ms Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Main CircuitFlexible 2 x 70 ... 185 mm² Rigid Al-Cable 1 x 185 ... 240 mm² Rigid Cu-Cable 1 x 6 ... 300 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 2 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(600 V AC) 350 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 40 Hp (200 V AC) Three Phase 100 hp (208 V AC) Three Phase 100 hp (220 ... 240 V AC) Three Phase 50 Hp (220 ... 240 V AC) Three Phase 125 hp (440 ... 480 V AC) Three Phase 100 Hp (440 ... 480 V AC) Three Phase 250 hp (550 ... 600 V AC) Three Phase 150 Hp (550 ... 600 V AC) Three Phase 300 hp
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3707238
E-Number (Norway)4117789
E-Number (Sweden)3210344
Manufacturer ID1SFL587102R1311

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp