Industrial Automation Parts. Prompt replies from real people.

ABB AF305B-30-22-12 3-Pole Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB AF305B-30-22-12?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AF305B-30-22-12 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AF305B-30-22-12
Material Number
1SFL587063R1222
Manufacturer
ABB
Product ID
84185

Get a Free Quote

Request pricing and availability for AF305B-30-22-12.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
3.9 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A (1000 V) 60 °C 325 A (1000 V) 70 °C 260 A (690 V) 40 °C 500 A (690 V) 60 °C 400 A (690 V) 70 °C 325 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW (440 V) 160 kW (500 V) 200 kW (690 V) 250 kW (1000 V) 185 kW (380 / 400 V) 160 kW (220 / 230 / 240 V) 90 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Maximum Mechanical Switching Frequency
300 cycles per hour
See all specifications

Product Highlights

  1. Contact Configuration: 3 NO main contacts, 2 NO auxiliary contacts, and 2 NC auxiliary contacts
  2. Rated Operational Voltage: Main circuit 1000 V
  3. AC-3 Motor Ratings: 305 A at 220 to 440 V, 290 A at 500 to 690 V, and 100 A at 1000 V, all at 55 °C
  4. AC-3 Motor Power: 90 kW at 220 to 240 V, 160 kW at 380 to 440 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V
  5. Control Circuit: 48 to 130 V DC coil, with 340 V·A pull-in and 17 V·A holding at 50/60 Hz
  6. Mechanical Durability: 5 million operating cycles, maximum 300 cycles per hour
  7. Terminals and Dimensions: Main circuit bar terminals, 140 mm wide, 180 mm deep, 225 mm high, 3.9 kg
AF305B-30-22-12

Product Information

Technical Specifications

Specifications for AF305B-30-22-12

ParameterValue
Product Net Width140 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight3.9 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 1000 V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 375 A (1000 V) 60 °C 325 A (1000 V) 70 °C 260 A (690 V) 40 °C 500 A (690 V) 60 °C 400 A (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 305 A (440 V) 55 °C 305 A (500 V) 55 °C 290 A (690 V) 55 °C 290 A (1000 V) 55 °C 100 A (380400 V) 55 °C 305 A (220230240 V) 55 °C 305 A
Rated Operational Power AC-3 (Pe)(415 V) 160 kW (440 V) 160 kW (500 V) 200 kW (690 V) 250 kW (1000 V) 185 kW (380400 V) 160 kW (220230240 V) 90 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 40 °C 500 A (100 V) 1 Pole, 60 °C 400 A (100 V) 1 Pole, 70 °C 325 A (110 V) 1-Pole, 40 °C 500 A (110 V) 1-Pole, 60 °C 400 A (110 V) 1-Pole, 70 °C 325 A (110 V) 2 Poles in Series, 40 °C 500 A (110 V) 2 Poles in Series, 60 °C 400 A (110 V) 2 Poles in Series, 70 °C 325 A (110 V) 3 Poles in Series, 40 °C 500 A (110 V) 3 Poles in Series, 60 °C 400 A (110 V) 3 Poles in Series, 70 °C 325 A (175 V) 2 Poles in Series, 40 °C 500 A (175 V) 2 Poles in Series, 60 °C 400 A (175 V) 2 Poles in Series, 70 °C 325 A (200 V) 2 Poles in Series, 40 °C 500 A (200 V) 2 Poles in Series, 60 °C 400 A (200 V) 2 Poles in Series, 70 °C 325 A (220 V) 2 Poles in Series, 40 °C 500 A (220 V) 2 Poles in Series, 60 °C 400 A (220 V) 2 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 500 A (220 V) 3 Poles in Series, 60 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (260 V) 3 Poles in Series, 40 °C 500 A (260 V) 3 Poles in Series, 60 °C 400 A (260 V) 3 Poles in Series, 70 °C 325 A (300 V) 3 Poles in Series, 40 °C 500 A (300 V) 3 Poles in Series, 60 °C 400 A (300 V) 3 Poles in Series, 70 °C 325 A (340 V) 3 Poles in Series, 40 °C 500 A (340 V) 3 Poles in Series, 60 °C 400 A (340 V) 3 Poles in Series, 70 °C 325 A (72 V) 1-Pole, 40 °C 500 A (72 V) 1-Pole, 60 °C 400 A (72 V) 1-Pole, 70 °C 325 A (72 V) 2 Poles in Series, 40 °C 500 A (72 V) 2 Poles in Series, 60 °C 400 A (72 V) 2 Poles in Series, 70 °C 325 A (72 V) 3 Poles in Series, 40 °C 500 A (72 V) 3 Poles in Series, 60 °C 400 A (72 V) 3 Poles in Series, 70 °C 325 A (90 V) 1 Pole, 40 °C 500 A (90 V) 1 Pole, 60 °C 400 A (90 V) 1 Pole, 70 °C 325 A
ParameterValue
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 60 °C 400 A (110 V) 2 Poles in Series, 70 °C 325 A (110 V) 3 Poles in Series, 40 °C 400 A (110 V) 3 Poles in Series, 60 °C 400 A (110 V) 3 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 60 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (72 V) 2 Poles in Series, 40 °C 400 A (72 V) 2 Poles in Series, 60 °C 400 A (72 V) 2 Poles in Series, 70 °C 325 A (72 V) 3 Poles in Series, 40 °C 400 A (72 V) 3 Poles in Series, 60 °C 400 A (72 V) 3 Poles in Series, 70 °C 325 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 60 °C 400 A (110 V) 2 Poles in Series, 70 °C 325 A (110 V) 3 Poles in Series, 40 °C 400 A (110 V) 3 Poles in Series, 60 °C 400 A (110 V) 3 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 60 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (72 V) 2 Poles in Series, 40 °C 400 A (72 V) 2 Poles in Series, 60 °C 400 A (72 V) 2 Poles in Series, 70 °C 325 A (72 V) 3 Poles in Series, 40 °C 400 A (72 V) 3 Poles in Series, 60 °C 400 A (72 V) 3 Poles in Series, 70 °C 325 A
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 48 ... 130 V DC Operation 48 ... 130 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 17 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 17 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 340 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 340 V·A Pull-in at Max. Rated Control Circuit Voltage DC 360 W
Terminal TypeMain Circuit: Bars
General Use Rating UL/CSA(600 V AC) 400 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 100 hp (220 ... 240 V AC) Three Phase 125 hp (440 ... 480 V AC) Three Phase 250 hp (550 ... 600 V AC) Three Phase 300 hp
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Sweden)3210453
Manufacturer ID1SFL587063R1222