- AF305-40-11-12
ABB AF305-40-11-12 AC contactor, manufacturer ID 1SFL587102R1211. Four main contacts NO and no main contacts NC; one auxiliary contact NO and one NC. Main circuit rated operational voltage 1000 V at 50 Hz. Rated operational current AC-3 is 305 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 380/400 V, 415 V, and 440 V, and 90 kW at 220/230/240 V. Rated control circuit voltage is 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Dimensions are 184 mm wide, 180 mm deep, and 225.4 mm high; net weight 5.7 kg. Main circuit terminals are bars.
- AF305-40-11-13
ABB AF305-40-11-13 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V and 50 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 305 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 55 °C, corresponding to 160 kW at 380/400 V, 415 V, and 440 V, and 90 kW at 220/230/240 V. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 184 mm wide, 180 mm deep, and 225.4 mm high; weight is 5.7 kg.
- AF305-40-11-14
The ABB AF305-40-11-14 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. Main circuit rated operational voltage is 1000 V at 60 Hz. Rated operational current AC-3 is 305 A at 415 V, 440 V, and 380/400 V, each at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Conventional free-air thermal current is 500 A per IEC 60947-4-1 at 40 °C. Dimensions are 184 mm width, 180 mm depth, and 225.4 mm height; net weight 5.7 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF305-40-22-11
The ABB AF305-40-22-11 is a four-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 184 mm wide, 180 mm deep, and 225 mm high, and weighs 5.7 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 380/400 V, 415 V, and 440 V, and 90 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 630 A.
- AF305-40-22-12
ABB AF305-40-22-12 AC contactor, manufacturer ID 1SFL587102R1222. Four main contacts NO, zero NC, plus two auxiliary contacts NO and two NC. Main circuit rated operational voltage 1000 V, rated frequency 60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors, 40 °C: 500 A. Rated operational current AC-1: 500 A at 690 V, 40 °C; 375 A at 1000 V, 40 °C. Rated operational power AC-3: 160 kW at 380/400 V, 415 V, and 440 V; 90 kW at 220/230/240 V. Rated insulation voltage per IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V; per UL/CSA 600 V. Rated impulse withstand voltage 8 kV. Short-circuit protective devices: gG type fuses 630 A. Main circuit terminals: bars. Dimensions 184 mm width, 180 mm depth, 225 mm height; net weight 5.7 kg.
- AF305-40-22-13
The ABB AF305-40-22-13 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It includes two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high; net weight is 5.7 kg.
- AF305-40-22-14
The ABB AF305-40-22-14 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It carries two normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V and 50 Hz. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 90 kW at 220/230/240 V. Rated operational current AC-3 is 305 A at 55 °C for those voltages. Dimensions are 184 mm wide, 180 mm deep, and 225 mm high, with a net weight of 5.7 kg. Main terminals are bars; main terminals are IP00 and coil terminals IP20. Mechanical durability is 5 million operations.
- AF305B-30-22-11
ABB AF305B-30-22-11 is a 3-pole AC contactor, manufacturer ID 1SFL587063R1122. It has 3 main contacts NO, 0 main contacts NC, and 2 auxiliary contacts NO plus 2 auxiliary contacts NC. Rated operational voltage for the main circuit is 1000 V. Rated operational power AC-3 is 160 kW at 415 V, 160 kW at 440 V, 200 kW at 500 V, 250 kW at 690 V, and 185 kW at 1000 V. Rated control circuit voltage is 24 to 60 V DC and 24 to 60 V AC at 50 Hz or 60 Hz. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Mechanical durability is 5 million operations, with a maximum mechanical switching frequency of 300 cycles per hour. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.