- AFS12-30-22-11
The ABB AFS12-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 7.5 kW at 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AFS12-30-22-13
ABB AFS12-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Rated operational power AC-3 is 5.5 kW at 400 V, 415 V, 440 V, and 380/400 V, 7.5 kW at 500 V and 690 V, and 3 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFS12Z-30-22-30
The ABB AFS12Z-30-22-30 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It carries two normally open and two normally closed front-mounted auxiliary contacts. The contactor is rated 690 V for both main and auxiliary circuits at 50/60 Hz. AC-3 ratings include 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, all at 60 °C. Corresponding AC-3 power ratings are 5.5 kW at 400 V and 7.5 kW at 500 V and 690 V. It measures 45 mm wide, 130.5 mm deep, and 86 mm high, weighing 0.49 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AFS146-30-12-11
The ABB AFS146-30-12-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V.
- AFS146-30-12-12
ABB AFS146-30-12-12 AC contactor, manufacturer ID 1SFL467081R1212. Three main contacts NO, zero NC; auxiliary contacts: one NO and two NC. Main circuit rated operational voltage 1000 V at 50/60 Hz. Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, 40 °C: 225 A. Rated operational current AC-3: 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, 60 A at 1000 V, all at 60 °C. Rated operational power AC-3: 75 kW at 415 V, 90 kW at 440 V, 500 V, and 690 V, 75 kW at 1000 V. Dimensions: 90 mm width, 126 mm depth/length, 150 mm height; net weight 1.3 kg.
- AFS146-30-12-14
The ABB AFS146-30-12-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, each at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg. Manufacturer ID: 1SFL467081R1412.
- AFS146-30-12-33
The ABB AFS146-30-12-33 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. Its main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AFS146-30-12-34
ABB AFS146-30-12-34 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.3 kg.