Product Model
UA95-30-00RA-84
Material Number
1SFL431024R8400
Manufacturer
ABB
Product ID
83726

Get a Free Quote

Request pricing and availability for UA95-30-00RA-84.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.8 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 Hz
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 145 A (690 V) 55 °C 135 A (690 V) 60 °C 135 A (690 V) 70 °C 115 A
Rated Operational Power AC-3 (Pe)
(380 / 400 V) 45 kW
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
See all specifications

Product Highlights

  1. Capacitor Switching Duty: Classified as a capacitor contactor (ETIM EC001079) with AC-6b ratings from 30 kvar at 230/240 V and 70 °C to 120 kvar at 690 V and 40 °C
  2. Main Contacts: 3 normally open main poles with no normally open or normally closed auxiliary contacts
  3. Switching Capacity: AC-3 making capacity 10 x Ie and breaking capacity 8 x Ie, with maximum breaking capacity of 1160 A at 440 V and 800 A at 690 V
  4. Current Ratings: Conventional free-air thermal current 145 A at 40 °C, AC-1 145 A at 40 °C and 115 A at 70 °C, and AC-3 96 A at 380/400 V and 30 A at 1000 V
  5. Coil and Operating Range: Rated control circuit voltage 110 V at 50 Hz and 110 to 120 V at 60 Hz, operating limits 0.85 to 1.1 x Uc, with pull-in consumption up to 450 V·A and holding consumption up to 26 V·A
UA95-30-00RA-84

Product Information

Technical Specifications

Specifications for UA95-30-00RA-84

ParameterValue
Product Net Width90 mm
Product Net Depth / Length155.6 mm
Product Net Height170 mm
Product Net Weight1.8 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 145 A (690 V) 55 °C 135 A (690 V) 60 °C 135 A (690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 96 A (440 V) 55 °C 93 A (500 V) 55 °C 80 A (690 V) 55 °C 65 A (1000 V) 55 °C 30 A (380400 V) 55 °C 96 A (220230240 V) 55 °C 96 A
Rated Operational Power AC-3 (Pe)(380 / 400 V) 45 kW
Rated Operational Power AC-6b (Pe)(230240 V) 40 °C, 5060 Hz 40 kvar (230240 V) 55 °C, 5060 Hz 35 kvar (230240 V) 70 °C, 5060 Hz 30 kvar (400415 V) 40 °C, 5060 Hz 70 kvar (400415 V) 70 °C, 5060 Hz 53 kvar (400415 V) 55 °C, 5060 Hz 60 kvar (440 V) 40 °C, 5060 Hz 75 kvar (440 V) 55 °C, 5060 Hz 65 kvar (440 V) 70 °C, 5060 Hz 58 kvar (500550 V), 40 °C, 5060 Hz 85 kvar (500550 V) 55 °C, 5060 Hz 75 kvar (500550 V) 70 °C, 5060 Hz 70 kvar (690 V) 40 °C, 5060 Hz 120 kvar (690 V) 55 °C, 5060 Hz 105 kvar (690 V) 70 °C, 5060 Hz 85 kvar
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
ParameterValue
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 110 V 60 Hz 110 ... 120 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 15 ms Between Coil Energization and NO Contact Closing 10 ... 25 ms
Connecting Capacity Main CircuitBar 30 mm² Flexible with Cable End 2 x 6 ... 35 mm² Rigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 1 x 1 ... 4 mm² Stranded 2 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM8 hexagon socket screw with single connector
Terminal TypeCable Clamp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Object Classification CodeQ
ETIM 7EC001079 - Capacitor contactor
ETIM 8EC001079 - Capacitor contactor
ETIM 9EC001079 - Capacitor contactor
eClassV11.0 : 27371006
UNSPSC39121529
IDEA Granular Category Code (IGCC)4756 >> Capacitor magnet contactor
Manufacturer ID1SFL431024R8400

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.