- UA95-30-11-83
ABB UA95-30-11-83 is a three-phase AC contactor, manufacturer ID 1SFL431022R8311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1, open contactors, at 40 °C. Rated operational power AC-3 is 45 kW at 380/400 V. AC-6b ratings include 35 kvar at 230/240 V for 40 °C and 55 °C, and 30 kvar at 70 °C, all at 50/60 Hz. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.8 kg.
- UA95-30-11-84
ABB UA95-30-11-84 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power AC-3 is 45 kW at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations, with maximum mechanical switching frequency 3600 cycles per hour. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.8 kg.
- UA95-30-11-85
ABB UA95-30-11-85 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power is 45 kW in AC-3 at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations, with maximum mechanical switching frequency of 3600 cycles per hour.
- UA95-30-11-86
The ABB UA95-30-11-86 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power AC-3 is 45 kW at 380/400 V. Mechanical durability is 10 million operating cycles, with a maximum mechanical switching frequency of 3600 cycles per hour and maximum electrical switching frequency of 240 cycles per hour. Rated impulse withstand voltage for the main circuit is 8 kV.
- UA95-30-11-88
The ABB UA95-30-11-88 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V and 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power AC-3 is 45 kW at 380/400 V. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage for the main circuit is 8 kV. Mechanical durability is 10 million operations. Maximum mechanical switching frequency is 3600 cycles per hour; maximum electrical switching frequency is 240 cycles per hour. Cable clamp terminals are used.
- UA95-30-11RA-80
The ABB UA95-30-11RA-80 is a three-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 155.6 mm deep, and 170 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V and 50 Hz. Conventional free-air thermal current is 145 A at 40 °C, per IEC 60947-4-1 for open contactors. Rated operational current AC-3 is 96 A at 415 V and 55 °C, and rated operational power AC-3 is 45 kW at 380/400 V. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 Group C, and 600 V per UL/CSA.
- UA95-30-11RA-86
ABB UA95-30-11RA-86 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It has a rated operational voltage of 1000 V in the main circuit and a rated frequency of 50 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 380/400 V and 55 °C, and rated operational power AC-3 is 45 kW at 380/400 V. Maximum breaking capacity is 1160 A at 440 V and 800 A at 690 V. Dimensions are 102 mm wide, 155.6 mm deep, and 170 mm high, with a net weight of 1.8 kg.
- UA95-30-11RA-88
The ABB UA95-30-11RA-88 is a 3-phase AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It has a rated operational voltage of 1000 V for the main circuit and a rated frequency of 50 Hz. The conventional free-air thermal current is 145 A at 40°C according to IEC 60947-4-1 for open contactors. Rated operational current AC-3 is 96 A at 415 V and 55°C, and rated operational power AC-3 is 45 kW at 380/400 V. The contactor measures 102 mm wide, 155.6 mm deep, and 170 mm high, and weighs 1.8 kg. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA.