ABB UA95-30-11-86 400-415V 50Hz Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB UA95-30-11-86?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB UA95-30-11-86 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
UA95-30-11-86
Material Number
1SFL431022R8611
Manufacturer
ABB
Product ID
89353

Get a Free Quote

Request pricing and availability for UA95-30-11-86.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.8 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Rated Operational Power AC-3 (Pe)
(380 / 400 V) 45 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
See all specifications

Product Highlights

  1. Mechanical Durability: Rated for 10 million mechanical operating cycles
  2. Contact Configuration: 3 NO main contacts, 1 NO auxiliary contact, and 1 NC auxiliary contact
  3. Main Circuit Ratings: 1000 V rated operational voltage, 145 A conventional free-air thermal current at 40 °C, and 45 kW AC-3 rating at 380/400 V
  4. Capacitor Switching Capacity: AC-6b ratings from 30 to 80 kvar depending on voltage and ambient temperature, up to 690 V
  5. Coil and Frequency: 50/60 Hz rated frequency with control circuit voltage of 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz
UA95-30-11-86

Product Information

Technical Specifications

Specifications for UA95-30-11-86

ParameterValue
Product Net Width102 mm
Product Net Depth / Length123.5 mm
Product Net Height148 mm
Product Net Weight1.8 kg
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Power AC-3 (Pe)(380 / 400 V) 45 kW
Rated Operational Power AC-6b (Pe)(230240 V) 40 °C, 5060 Hz 35 kvar (230240 V) 55 °C, 5060 Hz 35 kvar (230240 V) 70 °C, 5060 Hz 30 kvar (400415 V) 40 °C, 5060 Hz 65 kvar (400415 V) 70 °C, 5060 Hz 55 kvar (400415 V) 55 °C, 5060 Hz 65 kvar (440 V) 40 °C, 5060 Hz 65 kvar (440 V) 55 °C, 5060 Hz 65 kvar (440 V) 70 °C, 5060 Hz 55 kvar (500550 V), 40 °C, 5060 Hz 70 kvar (500550 V) 55 °C, 5060 Hz 70 kvar (500550 V) 70 °C, 5060 Hz 60 kvar (690 V) 40 °C, 5060 Hz 80 kvar (690 V) 55 °C, 5060 Hz 80 kvar (690 V) 70 °C, 5060 Hz 70 kvar
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency240 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
ParameterValue
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 400 ... 415 V 60 Hz 415 ... 440 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 15 ms Between Coil De-energization and NO Contact Opening 10 ... 18 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Between Coil Energization and NO Contact Closing 10 ... 25 ms
Connecting Capacity Main CircuitBar 30 mm² Flexible with Cable End 2 x 6 ... 35 mm² Rigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM8 hexagon socket screw with single connector
Terminal TypeCable Clamp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Object Classification CodeQ
ETIM 7EC001079 - Capacitor contactor
ETIM 8EC001079 - Capacitor contactor
ETIM 9EC001079 - Capacitor contactor
eClassV11.0 : 27371006
UNSPSC39121529
IDEA Granular Category Code (IGCC)4756 >> Capacitor magnet contactor
Manufacturer ID1SFL431022R8611

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.