- OT400ES40K
ABB OT400ES40K isolating switch, 4-pole, base mounting, side operated with a direct mounted pistol-type handle. Conventional free-air thermal current is 400 A at 40 °C; conventional thermal current fully enclosed is 400 A. Rated operational current is 400 A at 380–415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power AC-23A is 132 kW at 220–240 V, 230 kW at 400–415 V, 280 kW at 500 V, and 400 kW at 690 V. Rated insulation voltage is 1000 V per IEC/EN 60664-1; rated impulse withstand voltage is 12 kV. Rated short-time withstand current is 15 kA for 1 s; rated short-circuit making capacity is 65 kA at 690 V. Standards: IEC 60947-3. Dimensions 295 x 185 x 107 mm; 4.1 kg.
- OT400ESUR3TZ
ABB OT400ESUR3TZ is a front-operated, non-fusible isolating switch in a stainless steel enclosure. It has 3 poles and a conventional thermal current (Ithe) of 400 A fully enclosed. The enclosure is rated IP65 according to IEC 60529, with pollution degree 3 and housing impact resistance IK09. Dimensions are 400 mm wide, 800 mm high, and 230 mm deep; net weight is 32.75 kg. Cable entry is bottom/bottom, with blank or 4x ring-flange plus 25.5 mm outlets per side. Main circuit connection uses a 10 mm hole diameter screw clamp, with PE terminal 4 pc, 25 to 120 mm². Mounted auxiliary contacts are 2 NO and 1 NC; maximum mounted auxiliary contacts are 2 NO and 2 NC. The pistol handle is stainless steel.
- OT400ESUR6TZ
ABB OT400ESUR6TZ is an enclosed isolating switch-disconnector in a stainless steel enclosure with a pistol handle. It is a 6-pole device rated 400 A conventional thermal current (fully enclosed) and 1000 V rated operational voltage. Rated operational current is 400 A at 380–415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 220 kW at 380–415 V, 280 kW at 500 V, and 355 kW at 690 V. Rated insulation voltage is 1000 V per IEC/EN 60664-1, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 61.5 kA, and rated short-time withstand current 15 kA for 1 s. Enclosure protection is IP65 per IEC 60529, impact resistance IK09, pollution degree 3. It has 4 NO and 2 NC auxiliary contacts. Dimensions are 800 mm wide, 800 mm high, and 230 mm deep; net weight 50.14 kg. Standards: IEC 60947-1, -3.
- OT400M03M1P
ABB isolating switch OT400M03M1P, manufacturer ID 1SCA022750R4110, is a 3-pole base-mounting switch disconnector with front operation and a mechanism at the left end of the switch. It is rated 400 A at 400 V for AC-21A and AC-22A, with conventional free-air thermal current 400 A at 40 °C and fully enclosed thermal current 400 A. Rated operational voltage of the main circuit is 1000 V, rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Rated short-circuit making capacity is 65 kA at 400 V; rated short-time withstand current is 15 kA for 1 s. Power loss is 10 W per pole at rated operating conditions. Terminal type is lug terminals, tightening torque 30 to 44 N·m according to IEC 60947-1. Dimensions are 191 mm width, 185 mm height, 85 mm depth; net weight 3.3 kg. Standards: IEC 60947-3.
- OT400M04M1P
ABB OT400M04M1P isolating switch, 4-pole, front-operated, base mounting. Rated operational voltage 1000 V; rated insulation voltage 1000 V acc. to IEC/EN 60664-1; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current fully enclosed 400 A. Rated operational current AC-21A and AC-22A 400 A at 400 V. Rated short-circuit making capacity 65 kA at 400 V; rated short-time withstand current 15 kA for 1 s. Standards: IEC 60947-3. Front degree of protection IP00; pollution degree 3. Lug terminals; tightening torque 30 to 44 N·m acc. IEC 60947-1. Black handle and shaft included, padlockable. Fourth pole right side, switched simultaneous. Mechanical durability 16000. Dimensions 235 x 185 x 85 mm; 4 kg.
- OT400U02
The ABB OT400U02 is a 2-pole, front-operated isolating switch intended for base mounting. Its conventional thermal current (Ithe) is 400 A fully enclosed. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Power loss at rated operating conditions is 10 W per pole. The switch has a pollution degree of 3 and front degree of protection IP00. Dimensions are 167 mm wide, 220 mm high, and 105 mm deep; net weight is 2.3 kg (5.1 lb). Mechanical durability is 16000 operating cycles. A handle and shaft are not included, and the lock type is no. Manufacturer ID: 1SCA022748R1140.
- OT400U02P
The ABB OT400U02P is a 2-pole isolating switch for base mounting, front operated, with a black handle and shaft included. It is rated for a conventional thermal current (Ithe) of 400 A fully enclosed, a rated impulse withstand voltage (Uimp) of 12 kV, and pollution degree 3. Power loss is 10 W per pole at rated operating conditions. Mechanical durability is 16000 operations. The front degree of protection is IP00. Dimensions are 167 mm wide, 220 mm high, and 105 mm deep; net weight is 2.7 kg (5.9 lb). The switch includes a lock type. Manufacturer ID: 1SCA022748R1310.
- OT400U03
ABB OT400U03 is a 3-pole, front-operated non-fusible isolating switch for base mounting. It is rated for a conventional thermal current (Ithe) of 400 A fully enclosed, with a rated impulse withstand voltage (Uimp) of 12 kV and pollution degree 3. Power loss is 10 W per pole at rated operating conditions. Line terminals may be configured top in - bottom out or bottom in - top out. The switch measures 221 mm wide, 220 mm high, and 105 mm deep, and weighs 3 kg (6.7 lb). Mechanical durability is 16000 operations. Front degree of protection is IP00. Handle and shaft are not included. Manufacturer ID: 1SCA022747R6490.