- OT400M03M1P
ABB isolating switch OT400M03M1P, manufacturer ID 1SCA022750R4110, is a 3-pole base-mounting switch disconnector with front operation and a mechanism at the left end of the switch. It is rated 400 A at 400 V for AC-21A and AC-22A, with conventional free-air thermal current 400 A at 40 °C and fully enclosed thermal current 400 A. Rated operational voltage of the main circuit is 1000 V, rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Rated short-circuit making capacity is 65 kA at 400 V; rated short-time withstand current is 15 kA for 1 s. Power loss is 10 W per pole at rated operating conditions. Terminal type is lug terminals, tightening torque 30 to 44 N·m according to IEC 60947-1. Dimensions are 191 mm width, 185 mm height, 85 mm depth; net weight 3.3 kg. Standards: IEC 60947-3.
- OT400M04M1P
ABB OT400M04M1P isolating switch, 4-pole, front-operated, base mounting. Rated operational voltage 1000 V; rated insulation voltage 1000 V acc. to IEC/EN 60664-1; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 400 A at 40 °C; conventional thermal current fully enclosed 400 A. Rated operational current AC-21A and AC-22A 400 A at 400 V. Rated short-circuit making capacity 65 kA at 400 V; rated short-time withstand current 15 kA for 1 s. Standards: IEC 60947-3. Front degree of protection IP00; pollution degree 3. Lug terminals; tightening torque 30 to 44 N·m acc. IEC 60947-1. Black handle and shaft included, padlockable. Fourth pole right side, switched simultaneous. Mechanical durability 16000. Dimensions 235 x 185 x 85 mm; 4 kg.
- OT400U02
The ABB OT400U02 is a 2-pole, front-operated isolating switch intended for base mounting. Its conventional thermal current (Ithe) is 400 A fully enclosed. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Power loss at rated operating conditions is 10 W per pole. The switch has a pollution degree of 3 and front degree of protection IP00. Dimensions are 167 mm wide, 220 mm high, and 105 mm deep; net weight is 2.3 kg (5.1 lb). Mechanical durability is 16000 operating cycles. A handle and shaft are not included, and the lock type is no. Manufacturer ID: 1SCA022748R1140.
- OT400U02P
The ABB OT400U02P is a 2-pole isolating switch for base mounting, front operated, with a black handle and shaft included. It is rated for a conventional thermal current (Ithe) of 400 A fully enclosed, a rated impulse withstand voltage (Uimp) of 12 kV, and pollution degree 3. Power loss is 10 W per pole at rated operating conditions. Mechanical durability is 16000 operations. The front degree of protection is IP00. Dimensions are 167 mm wide, 220 mm high, and 105 mm deep; net weight is 2.7 kg (5.9 lb). The switch includes a lock type. Manufacturer ID: 1SCA022748R1310.
- OT400U03
ABB OT400U03 is a 3-pole, front-operated non-fusible isolating switch for base mounting. It is rated for a conventional thermal current (Ithe) of 400 A fully enclosed, with a rated impulse withstand voltage (Uimp) of 12 kV and pollution degree 3. Power loss is 10 W per pole at rated operating conditions. Line terminals may be configured top in - bottom out or bottom in - top out. The switch measures 221 mm wide, 220 mm high, and 105 mm deep, and weighs 3 kg (6.7 lb). Mechanical durability is 16000 operations. Front degree of protection is IP00. Handle and shaft are not included. Manufacturer ID: 1SCA022747R6490.
- OT400U03-1000
The ABB OT400U03-1000 is a 3-pole isolating switch with a rated operational voltage of 1000 V in the main circuit and a rated impulse withstand voltage of 12 kV. It has a rated short-time withstand current of 15 kA for 1 s and power loss of 10 W per pole at rated operating conditions. Dimensions are 221 mm wide, 220 mm high, and 105 mm deep, weighing 3.0 kg. It is designed to UL 98 and CSA C22.2 NO.4.
- OT400U03C
The ABB OT400U03C is a 3-pole isolating switch with manufacturer ID 1SCA022771R2990. It is rated for a conventional free-air thermal current (Ith) of 400 A at 40 °C, with a rated impulse withstand voltage (Uimp) of 12 kV. The switch has front IP20 degree of protection and pollution degree 3. It is front operated with base mounting, and line terminals can be configured as top in - bottom out or bottom in - top out. Mechanical durability is 8000 cycles. Power loss is 10 W per pole at rated operating conditions. Dimensions are 251 mm width, 185 mm height, and 203 mm depth, with a net weight of 5.46 kg. Handle and shaft are not included.
- OT400U03CP
ABB OT400U03CP is a 3-pole front-operated change-over isolating switch, base mounting, with handle and shaft included. It is rated 400 A conventional free-air thermal current (Ith) at 40 °C, with rated impulse withstand voltage (Uimp) 12 kV and power loss at rated operating conditions per pole 10 W. Pollution degree 3; front degree of protection IP20. Line terminals may be configured top in - bottom out or bottom in - top out. Mechanical durability is 8000 cycles. Dimensions: 251 mm width, 185 mm height, 203 mm depth; net weight 4.7 kg. Manufacturer ID 1SCA022771R2810.