- OT400U03-1000
The ABB OT400U03-1000 is a 3-pole isolating switch with a rated operational voltage of 1000 V in the main circuit and a rated impulse withstand voltage of 12 kV. It has a rated short-time withstand current of 15 kA for 1 s and power loss of 10 W per pole at rated operating conditions. Dimensions are 221 mm wide, 220 mm high, and 105 mm deep, weighing 3.0 kg. It is designed to UL 98 and CSA C22.2 NO.4.
- OT400U03C
The ABB OT400U03C is a 3-pole isolating switch with manufacturer ID 1SCA022771R2990. It is rated for a conventional free-air thermal current (Ith) of 400 A at 40 °C, with a rated impulse withstand voltage (Uimp) of 12 kV. The switch has front IP20 degree of protection and pollution degree 3. It is front operated with base mounting, and line terminals can be configured as top in - bottom out or bottom in - top out. Mechanical durability is 8000 cycles. Power loss is 10 W per pole at rated operating conditions. Dimensions are 251 mm width, 185 mm height, and 203 mm depth, with a net weight of 5.46 kg. Handle and shaft are not included.
- OT400U03CP
ABB OT400U03CP is a 3-pole front-operated change-over isolating switch, base mounting, with handle and shaft included. It is rated 400 A conventional free-air thermal current (Ith) at 40 °C, with rated impulse withstand voltage (Uimp) 12 kV and power loss at rated operating conditions per pole 10 W. Pollution degree 3; front degree of protection IP20. Line terminals may be configured top in - bottom out or bottom in - top out. Mechanical durability is 8000 cycles. Dimensions: 251 mm width, 185 mm height, 203 mm depth; net weight 4.7 kg. Manufacturer ID 1SCA022771R2810.
- OT400U03DP
The ABB OT400U03DP is a front-operated isolating switch supplied with handle and shaft. It has six poles and a conventional thermal current (Ithe) of 400 A fully enclosed. Rated operational current is 400 A at 380–415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated operational voltage of the main circuit is 1000 V; rated insulation voltage is 1000 V acc. to IEC/EN 60664-1, and rated impulse withstand voltage is 12 kV. Rated short-circuit making capacity (Icm) is 65 kA at 690 V, and rated short-time withstand current (Icw) is 15 kA for 1 s. Standards: IEC 60947-3, UL 98, CSA C22.2 NO.4. Maximum operating voltage UL/CSA is 600 V. Dimensions are 251 mm wide, 185 mm high, and 202.5 mm deep; net weight is 6.6 kg.
- OT400U03P
The ABB OT400U03P is a front-operated, 3-pole isolating switch supplied with handle and shaft. It is rated 400 A conventional free-air thermal current at 40 °C and 400 A conventional thermal current fully enclosed. Dimensions are 221 mm wide, 220 mm high, and 105 mm deep, with a net weight of 3.4 kg. The switch uses base mounting, has black handle, lockable mechanism, and 16000 mechanical operations. Line terminals can be configured top in/bottom out or bottom in/top out. Front degree of protection is IP00; pollution degree 3. Manufacturer ID 1SCA022718R9670.
- OT400U04
ABB OT400U04 is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301266D0201, Pollution Degree: 3, and Product Net Width: 275 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT400U04-1000
The ABB OT400U04-1000 is a 4-pole isolating switch. Rated operational voltage for the main circuit is 1000 V, with a maximum operating voltage of 1000 V per UL/CSA. Rated impulse withstand voltage (Uimp) is 12 kV, and rated short-time withstand current (Icw) is 15 kA for 1 s. Ampere rating is 200 A. Power loss is 25 W per pole at rated operating conditions. Dimensions are 220 mm high, 275 mm wide, and 105 mm deep; net weight is 3.8 kg. The switch is designed for base mounting and is classified under UL 98 and CSA C22.2 NO.4. Manufacturer ID: 1SCA159825R1001.
- OT400U04C
The ABB OT400U04C is a four-pole, front-operated isolating switch with a manufacturer ID of 1SCA022771R2210. It is rated for a conventional free-air thermal current (Ith) of 400 A at 40 °C. The fourth pole is switched with a simultaneous function and positioned on the right side. The switch is base mounted, has a black handle, and is supplied without a handle or shaft. Line terminals can be configured as top in - bottom out or bottom in - top out. Mechanical durability is 8000 cycles. The front degree of protection is IP20, and the pollution degree is 3. Net dimensions are 305 mm width, 185 mm height, and 203 mm depth, with a net weight of 7.66 kg.