- ESB25-40N-01
ABB ESB25-40N-01 building contactor, manufacturer ID 1SAE231111R0140. Four-pole (4 NO main contacts, no NC main or auxiliary contacts), 2 modular spacings wide. Rated operational voltage: main circuit 220 V DC and 400 V AC; rated control circuit voltage 24 V. Rated operational current AC-1 (NO) 25 A; AC-3 (NO) 9 A at 230 V single phase and 9 A at 400 V three phase. Rated operational power AC-1 (NO) 5.8 kW at 230 V single phase and 17.3 kW at 400 V three phase; AC-3 (NO) 1.3 kW and 4 kW respectively. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, IP20. Dimensions 36 x 85 x 65 mm, 0.245 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-40N-02
ABB building contactor ESB25-40N-02, manufacturer ID 1SAE231111M0240. Four-pole installation contactor with four normally open main contacts, no auxiliary contacts. Rated operational current 25 A at AC-1 and AC-7a; 9 A at AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 42 V. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. Degree of protection IP20. Ambient operating temperature -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-40N-03
ABB building contactor ESB25-40N-03, manufacturer ID 1SAE231111M0340. Four-pole installation contactor with four normally open main contacts and no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 48 V. Rated operational current AC-1 (NO) 25 A; AC-3 9 A at 230 V single phase and 9 A at 400 V three phase. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. IP20. Mechanical durability 1,000,000 cycles. Ambient operating temperature -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB25-40N-04
The ABB ESB25-40N-04 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 36 mm wide, 85 mm high, and 65 mm deep, and weighs 0.24 kg. Rated operational voltage is 220 V DC and 400 V AC on the main circuit; rated control circuit voltage is 110 to 120 V. Rated operational current is 25 A at AC-1 and AC-7a, and 9 A at AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, and mechanical durability is 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- ESB25-40N-06
The ABB ESB25-40N-06 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 36 mm wide, 85 mm high, and 65 mm deep, and weighs 0.235 kg. The main circuit is rated 220 V DC and 400 V AC; the control circuit voltage is 230 to 240 V. Rated operational current is 25 A in AC-1 and AC-7a, and 9 A in AC-3 and AC-7b at both 230 V single-phase and 400 V three-phase. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Mechanical durability is 1,000,000 cycles; electrical durability is 130,000 cycles in AC-1 and AC-7a, and 500,000 cycles in AC-3 and AC-7b. Degree of protection is IP20.
- ESB25-40N-07
The ABB ESB25-40N-07 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 36 mm wide, 85 mm high, and 65 mm deep, and weighs 0.235 kg. The main circuit is rated 220 V DC and 400 V AC; the control circuit voltage is 400 to 415 V. Rated operational current is 25 A in AC-1 and AC-7a, and 9 A in AC-3 at 230 V single-phase or 400 V three-phase. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, ambient operating temperature is -25 to +55 degrees C, and maximum operating altitude is 2000 m. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB25-40N-14
ABB building contactor ESB25-40N-14, manufacturer ID 1SAE231111M1440. Four-pole installation contactor with four normally open main contacts, no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 12 V. Rated operational current AC-1 (NO) 25 A; AC-3 (NO) 9 A at 230 V single phase and 9 A at 400 V three phase. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. IP20 degree of protection. Ambient air temperature for operation -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-20N-01
ABB ESB40-20N-01 building contactor with manufacturer ID 1SAE341111M0120. Two-pole (2 NO main contacts, no auxiliary contacts), rated operational current 40 A at AC-1 and AC-7a, 22 A at AC-3 and AC-7b (230 V single phase). Rated control circuit voltage 24 V; main circuit rated operational voltage 220 V DC and 400 V AC. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, IP20. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.37 kg. Main circuit connecting capacity rigid 1x 1.5 to 25 mm². Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Ambient operating temperature -25 to +55 °C.