- ESB25-40N-14
ABB building contactor ESB25-40N-14, manufacturer ID 1SAE231111M1440. Four-pole installation contactor with four normally open main contacts, no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 12 V. Rated operational current AC-1 (NO) 25 A; AC-3 (NO) 9 A at 230 V single phase and 9 A at 400 V three phase. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. IP20 degree of protection. Ambient air temperature for operation -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-20N-01
ABB ESB40-20N-01 building contactor with manufacturer ID 1SAE341111M0120. Two-pole (2 NO main contacts, no auxiliary contacts), rated operational current 40 A at AC-1 and AC-7a, 22 A at AC-3 and AC-7b (230 V single phase). Rated control circuit voltage 24 V; main circuit rated operational voltage 220 V DC and 400 V AC. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, IP20. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.37 kg. Main circuit connecting capacity rigid 1x 1.5 to 25 mm². Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Ambient operating temperature -25 to +55 °C.
- ESB40-20N-06
The ABB ESB40-20N-06 is an installation contactor for distribution boards with two normally open main contacts and no auxiliary contacts. It has a rated operational current of 40 A in AC-1 and AC-7a, and 22 A at 230 V single-phase in AC-3 and AC-7b. Rated operational voltage is 220 V DC and 400 V AC for the main circuit; rated control circuit voltage is 230 V. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.37 kg. Degree of protection is IP20, with a mechanical durability of 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB40-22N-01
The ABB ESB40-22N-01 is a four-pole building contactor with two normally open and two normally closed main contacts and no auxiliary contacts. It is rated 40 A AC-1 (NO) and 30 A AC-1 (NC), with 9.2 kW AC-1 (NO) and 6.9 kW AC-1 (NC) at 230 V single phase. The coil is rated 24 V. Main circuit rated operational voltage is 400 V AC and 220 V DC. Dimensions are 54 mm wide, 85 mm high and 65 mm deep, weight 0.405 kg, IP20, pollution degree 3, rated insulation voltage 500 V and rated impulse withstand voltage 6 kV. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1 and UL 60947-4-1.
- ESB40-22N-06
ABB ESB40-22N-06 building contactor, manufacturer ID 1SAE341111R0622. Four-pole device with two normally open and two normally closed main contacts, no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 230 V. Rated operational current AC-1: 40 A (NO), 30 A (NC); AC-3 at 230 V single phase, NO: 22 A. Rated operational power AC-1 at 230 V single phase: 9.2 kW (NO), 6.9 kW (NC); AC-3 at 230 V single phase, NO: 3.7 kW. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 54 x 85 x 65 mm, 0.405 kg, IP20, three modular spacings. Ambient operating temperature -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-30N-01
ABB building contactor ESB40-30N-01, manufacturer ID 1SAE341111M0130. Three-pole (3 NO main contacts, no auxiliary contacts) installation contactor for distribution boards. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 24 V. Rated operational current AC-1 (NO) 40 A; AC-3 (NO) 22 A at 230 V single-phase and 22 A at 400 V three-phase. Rated operational power AC-1 (NO) 9.2 kW at 230 V single-phase and 27.7 kW at 400 V three-phase; AC-3 (NO) 3.7 kW at 230 V single-phase and 11 kW at 400 V three-phase. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.385 kg. Degree of protection IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-30N-06
ABB building contactor ESB40-30N-06, manufacturer ID 1SAE341111M0630. Three-pole installation contactor with three normally open main contacts and no auxiliary contacts. Rated operational current AC-1 (NO) 40 A; AC-3 (NO) 22 A at 230 V single phase and 22 A at 400 V three phase. Rated operational power AC-1 (NO) 9.2 kW at 230 V single phase and 27.7 kW at 400 V three phase; AC-3 (NO) 3.7 kW at 230 V single phase and 11 kW at 400 V three phase. Rated control circuit voltage 230 V. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated frequency: control circuit 400 Hz, 50 Hz, 60 Hz, and DC; main circuit 50 Hz, 60 Hz, and DC. Dimensions 54 mm width, 85 mm height, 65 mm depth; net weight 0.385 kg. IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-30N-07
The ABB ESB40-30N-07 is a three-pole building contactor with three normally open main contacts and no auxiliary contacts. It measures 54 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.385 kg. Rated operational current is 40 A AC-1 (NO) and 22 A AC-3 at 230 V single-phase or 400 V three-phase. Rated operational voltage is 220 V DC and 400 V AC main circuit; rated control circuit voltage is 400 V. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, pollution degree 3, ambient operating temperature -25 to +55 °C, maximum operating altitude 2000 m. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.