- ESB25-40N-07
The ABB ESB25-40N-07 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It measures 36 mm wide, 85 mm high, and 65 mm deep, and weighs 0.235 kg. The main circuit is rated 220 V DC and 400 V AC; the control circuit voltage is 400 to 415 V. Rated operational current is 25 A in AC-1 and AC-7a, and 9 A in AC-3 at 230 V single-phase or 400 V three-phase. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20, ambient operating temperature is -25 to +55 degrees C, and maximum operating altitude is 2000 m. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB25-40N-14
ABB building contactor ESB25-40N-14, manufacturer ID 1SAE231111M1440. Four-pole installation contactor with four normally open main contacts, no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 12 V. Rated operational current AC-1 (NO) 25 A; AC-3 (NO) 9 A at 230 V single phase and 9 A at 400 V three phase. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 36 mm wide, 85 mm high, 65 mm deep; net weight 0.245 kg. IP20 degree of protection. Ambient air temperature for operation -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-20N-01
ABB ESB40-20N-01 building contactor with manufacturer ID 1SAE341111M0120. Two-pole (2 NO main contacts, no auxiliary contacts), rated operational current 40 A at AC-1 and AC-7a, 22 A at AC-3 and AC-7b (230 V single phase). Rated control circuit voltage 24 V; main circuit rated operational voltage 220 V DC and 400 V AC. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, IP20. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.37 kg. Main circuit connecting capacity rigid 1x 1.5 to 25 mm². Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Ambient operating temperature -25 to +55 °C.
- ESB40-20N-06
The ABB ESB40-20N-06 is an installation contactor for distribution boards with two normally open main contacts and no auxiliary contacts. It has a rated operational current of 40 A in AC-1 and AC-7a, and 22 A at 230 V single-phase in AC-3 and AC-7b. Rated operational voltage is 220 V DC and 400 V AC for the main circuit; rated control circuit voltage is 230 V. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.37 kg. Degree of protection is IP20, with a mechanical durability of 1,000,000 cycles. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB40-22N-01
The ABB ESB40-22N-01 is a four-pole building contactor with two normally open and two normally closed main contacts and no auxiliary contacts. It is rated 40 A AC-1 (NO) and 30 A AC-1 (NC), with 9.2 kW AC-1 (NO) and 6.9 kW AC-1 (NC) at 230 V single phase. The coil is rated 24 V. Main circuit rated operational voltage is 400 V AC and 220 V DC. Dimensions are 54 mm wide, 85 mm high and 65 mm deep, weight 0.405 kg, IP20, pollution degree 3, rated insulation voltage 500 V and rated impulse withstand voltage 6 kV. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1 and UL 60947-4-1.
- ESB40-22N-06
ABB ESB40-22N-06 building contactor, manufacturer ID 1SAE341111R0622. Four-pole device with two normally open and two normally closed main contacts, no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 230 V. Rated operational current AC-1: 40 A (NO), 30 A (NC); AC-3 at 230 V single phase, NO: 22 A. Rated operational power AC-1 at 230 V single phase: 9.2 kW (NO), 6.9 kW (NC); AC-3 at 230 V single phase, NO: 3.7 kW. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 54 x 85 x 65 mm, 0.405 kg, IP20, three modular spacings. Ambient operating temperature -25 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-30N-01
ABB building contactor ESB40-30N-01, manufacturer ID 1SAE341111M0130. Three-pole (3 NO main contacts, no auxiliary contacts) installation contactor for distribution boards. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 24 V. Rated operational current AC-1 (NO) 40 A; AC-3 (NO) 22 A at 230 V single-phase and 22 A at 400 V three-phase. Rated operational power AC-1 (NO) 9.2 kW at 230 V single-phase and 27.7 kW at 400 V three-phase; AC-3 (NO) 3.7 kW at 230 V single-phase and 11 kW at 400 V three-phase. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.385 kg. Degree of protection IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB40-30N-06
ABB building contactor ESB40-30N-06, manufacturer ID 1SAE341111M0630. Three-pole installation contactor with three normally open main contacts and no auxiliary contacts. Rated operational current AC-1 (NO) 40 A; AC-3 (NO) 22 A at 230 V single phase and 22 A at 400 V three phase. Rated operational power AC-1 (NO) 9.2 kW at 230 V single phase and 27.7 kW at 400 V three phase; AC-3 (NO) 3.7 kW at 230 V single phase and 11 kW at 400 V three phase. Rated control circuit voltage 230 V. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated frequency: control circuit 400 Hz, 50 Hz, 60 Hz, and DC; main circuit 50 Hz, 60 Hz, and DC. Dimensions 54 mm width, 85 mm height, 65 mm depth; net weight 0.385 kg. IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.