- DS201 M C6 APR30
The ABB DS201 M C6 APR30 is a DIN-rail mounted leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It has a rated current of 6 A and a rated residual current of 30 mA, with a rated short-circuit capacity of 10 kA and rated ultimate short-circuit breaking capacity (Icu) of 15 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage (Ui) is 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage (Uimp) is 4 kV. It is a 1P+N device with one protected pole and two poles total, occupying two modular spacings. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth, 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M C6 F30
The ABB DS201 M C6 F30 is a 1P+N leakage protection circuit breaker in a two-module DIN-rail package. It is rated 6 A with C tripping characteristic, 30 mA Type F residual current, and 240 V AC rated operational voltage per IEC 60898-1. Rated short-circuit capacity is 10 kA; rated ultimate short-circuit breaking capacity (Icu) is 15 kA and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz, rated impulse withstand voltage (Uimp) is 4 kV, and operating ambient air temperature is -25 to 55 °C. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with 2.8 N·m tightening torque.
- DS201 M K10 A100
The ABB DS201 M K10 A100 is a 1P+N residual current circuit breaker (RCBO) with a rated current of 10 A and rated residual current of 100 mA. It has a K tripping characteristic and Type A residual current detection. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage of 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 10 kA and rated ultimate short-circuit breaking capacity is 15 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail module spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Operating ambient air temperature range is -25 to 55 °C.
- DS201 M K13 A100
The ABB DS201 M K13 A100 is a 1P+N leakage protection circuit breaker with a Type A residual current device and K tripping characteristic. It is rated 13 A with a rated residual current of 100 mA and a rated short-circuit capacity of 10 kA. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. The device is compliant with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has a rated impulse withstand voltage of 4 kV and a rated insulation voltage of 500 V according to IEC/EN 60664-1. It is DIN-rail mounted with screw terminals, two modular spacings wide, and operates from -25 to 55 degrees C. The manufacturer ID is 2CSR275180R2137.
- DS201 M K16 A100
The ABB DS201 M K16 A100 is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A with a 100 mA Type A residual current. It has a K tripping characteristic and provides one protected pole in a two-pole, two-module DIN-rail housing measuring 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Rated operational voltage is 240 V AC per IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 M K25 A100
ABB DS201 M K25 A100 is a leakage protection circuit breaker with a K tripping characteristic and Type A residual current detection. It has a rated current of 25 A, rated residual current of 100 mA, and rated short-circuit capacity of 10 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, and occupies two modular spacings on DIN rail. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with 200 g net weight. Operating ambient temperature range is -25 to 55 °C.
- DS201 M K6 A100
The ABB DS201 M K6 A100 is a 1P+N leakage protection circuit breaker with a rated current of 6 A and a rated residual current of 100 mA. It uses Type A residual current detection and a K tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated impulse withstand voltage of 4 kV. It is rated 10 kA short-circuit capacity, 15 kA Icu, and 11.2 kA Ics. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, measures 35 mm by 85 mm by 69 mm, and weighs 200 g. Operating ambient air temperature is -25 to 55 degrees C. Screw terminals accept conductors up to 25 square millimeters.
- DS201T B10 A30
The ABB DS201T B10 A30 is a two-module leakage protection circuit breaker for traction applications. It has a B tripping characteristic, Type A residual current, 10 A rated current, and 30 mA rated residual current. Rated operational voltage is 230 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight 182 g. Operating ambient air temperature is -25 to 55 °C.