- DS201 M K13 A100
The ABB DS201 M K13 A100 is a 1P+N leakage protection circuit breaker with a Type A residual current device and K tripping characteristic. It is rated 13 A with a rated residual current of 100 mA and a rated short-circuit capacity of 10 kA. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. The device is compliant with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has a rated impulse withstand voltage of 4 kV and a rated insulation voltage of 500 V according to IEC/EN 60664-1. It is DIN-rail mounted with screw terminals, two modular spacings wide, and operates from -25 to 55 degrees C. The manufacturer ID is 2CSR275180R2137.
- DS201 M K16 A100
The ABB DS201 M K16 A100 is a 1P+N residual current circuit breaker with overcurrent protection, rated 16 A with a 100 mA Type A residual current. It has a K tripping characteristic and provides one protected pole in a two-pole, two-module DIN-rail housing measuring 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Rated operational voltage is 240 V AC per IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 M K25 A100
ABB DS201 M K25 A100 is a leakage protection circuit breaker with a K tripping characteristic and Type A residual current detection. It has a rated current of 25 A, rated residual current of 100 mA, and rated short-circuit capacity of 10 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, and occupies two modular spacings on DIN rail. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with 200 g net weight. Operating ambient temperature range is -25 to 55 °C.
- DS201 M K6 A100
The ABB DS201 M K6 A100 is a 1P+N leakage protection circuit breaker with a rated current of 6 A and a rated residual current of 100 mA. It uses Type A residual current detection and a K tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated impulse withstand voltage of 4 kV. It is rated 10 kA short-circuit capacity, 15 kA Icu, and 11.2 kA Ics. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, measures 35 mm by 85 mm by 69 mm, and weighs 200 g. Operating ambient air temperature is -25 to 55 degrees C. Screw terminals accept conductors up to 25 square millimeters.
- DS201T B10 A30
The ABB DS201T B10 A30 is a two-module leakage protection circuit breaker for traction applications. It has a B tripping characteristic, Type A residual current, 10 A rated current, and 30 mA rated residual current. Rated operational voltage is 230 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight 182 g. Operating ambient air temperature is -25 to 55 °C.
- DS201T B10 APR30
The ABB DS201T B10 APR30 is a leakage protection circuit breaker for traction applications. It has a B tripping characteristic, Type APR residual current, one protected pole, and two poles total. Rated current is 10 A with 30 mA rated residual current. Rated operational voltage is 230 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is DIN-rail mounted, 35 mm wide, 85 mm high, 69 mm deep, and weighs 182 g. Standards listed include IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545.
- DS201T B13 A30
The ABB DS201T B13 A30 is a Type A residual current circuit breaker with overcurrent protection, rated 13 A and 30 mA residual current, tripping characteristic B. It is rated for 230 V AC operation per IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and 50 to 60 Hz frequency. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, and rated service short-circuit breaking capacity 7.5 kA. It is a two-pole device with one protected pole, occupying two DIN-rail modular spacings, and is intended for traction applications. Standards cited are IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545.
- DS201T B13 APR30
The ABB DS201T B13 APR30 is a DIN-rail leakage protection circuit breaker with a rated current of 13 A, rated residual current of 30 mA, and B tripping characteristic. It has one protected pole and two poles total, occupying two modular spacings (35 mm wide, 85 mm high, 69 mm deep, 182 g). Rated operational voltage is 230 V AC according to IEC 60898-1; rated frequency is 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. Residual current type is Type APR with instantaneous APR high-immunity operating characteristic. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545. It is suitable for traction applications.