- DS201T B10 APR30
The ABB DS201T B10 APR30 is a leakage protection circuit breaker for traction applications. It has a B tripping characteristic, Type APR residual current, one protected pole, and two poles total. Rated current is 10 A with 30 mA rated residual current. Rated operational voltage is 230 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is DIN-rail mounted, 35 mm wide, 85 mm high, 69 mm deep, and weighs 182 g. Standards listed include IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545.
- DS201T B13 A30
The ABB DS201T B13 A30 is a Type A residual current circuit breaker with overcurrent protection, rated 13 A and 30 mA residual current, tripping characteristic B. It is rated for 230 V AC operation per IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and 50 to 60 Hz frequency. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, and rated service short-circuit breaking capacity 7.5 kA. It is a two-pole device with one protected pole, occupying two DIN-rail modular spacings, and is intended for traction applications. Standards cited are IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545.
- DS201T B13 APR30
The ABB DS201T B13 APR30 is a DIN-rail leakage protection circuit breaker with a rated current of 13 A, rated residual current of 30 mA, and B tripping characteristic. It has one protected pole and two poles total, occupying two modular spacings (35 mm wide, 85 mm high, 69 mm deep, 182 g). Rated operational voltage is 230 V AC according to IEC 60898-1; rated frequency is 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. Residual current type is Type APR with instantaneous APR high-immunity operating characteristic. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545. It is suitable for traction applications.
- DS201T B16 A30
ABB DS201T B16 A30 leakage protection circuit breaker, manufacturer ID 2CSR255188R1165. It is a 1P+N device with two modular spacings, rated 16 A and 30 mA residual current, type A, tripping characteristic B. Rated operational voltage is 230 V AC according to IEC 60898-1; rated insulation voltage is 500 V per IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is intended for traction applications and is suitable for traction applications. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545. DIN-rail mounting, screw terminals, 35 mm wide, 85 mm high, 69 mm deep, 182 g.
- DS201T B16 APR30
The ABB DS201T B16 APR30 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type APR residual current. It is rated 16 A with 30 mA residual current sensitivity, 230 V AC rated operational voltage per IEC 60898-1, and 50 to 60 Hz rated frequency. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA. It occupies two modular spacings on DIN rail, measuring 35 mm wide, 85 mm high, and 69 mm deep, with a net weight of 182 g. Standards include IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. Operating ambient air temperature is -25 to 55 °C. Screw terminals accept 0.75 to 25 mm² conductors.
- DS201T B40 A30
ABB DS201T B40 A30 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type A residual current. Rated current is 40 A and rated residual current is 30 mA. Rated operational voltage is 230 V AC according to IEC 60898-1; rated frequency is 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It has two poles, one protected pole, and two modular spacings. DIN-rail mounting, screw terminals, 2.8 N·m tightening torque, and 12 mm wire stripping length. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545. Operating ambient temperature is -25 to 55 °C. Dimensions are 35 mm width, 85 mm height, 69 mm depth; weight 182 g.
- DS201T B40 APR30
ABB DS201T B40 APR30 leakage protection circuit breaker, manufacturer ID 2CSR255488R1405. It is a two-pole RCBO with one protected pole, rated current 40 A, rated residual current 30 mA, tripping characteristic B, and Type APR residual current. Rated operational voltage is 230 V AC according to IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, and rated service short-circuit breaking capacity 7.5 kA. Maximum surge current is 3 kA. It is intended for traction applications and DIN-rail mounting, with screw terminals, 2 modular spacings, 35 mm width, and operating ambient air temperature -25 to 55 degrees C. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545.
- DS201T C10 A30
The ABB DS201T C10 A30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. Rated current is 10 A and rated residual current is 30 mA. Rated operational voltage is 230 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1, rated impulse withstand voltage is 4 kV, and dielectric test voltage is 2 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is intended for traction applications and is declared to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 182 g.