- DS201T B40 A30
ABB DS201T B40 A30 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type A residual current. Rated current is 40 A and rated residual current is 30 mA. Rated operational voltage is 230 V AC according to IEC 60898-1; rated frequency is 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It has two poles, one protected pole, and two modular spacings. DIN-rail mounting, screw terminals, 2.8 N·m tightening torque, and 12 mm wire stripping length. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545. Operating ambient temperature is -25 to 55 °C. Dimensions are 35 mm width, 85 mm height, 69 mm depth; weight 182 g.
- DS201T B40 APR30
ABB DS201T B40 APR30 leakage protection circuit breaker, manufacturer ID 2CSR255488R1405. It is a two-pole RCBO with one protected pole, rated current 40 A, rated residual current 30 mA, tripping characteristic B, and Type APR residual current. Rated operational voltage is 230 V AC according to IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity 10 kA, and rated service short-circuit breaking capacity 7.5 kA. Maximum surge current is 3 kA. It is intended for traction applications and DIN-rail mounting, with screw terminals, 2 modular spacings, 35 mm width, and operating ambient air temperature -25 to 55 degrees C. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545.
- DS201T C10 A30
The ABB DS201T C10 A30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. Rated current is 10 A and rated residual current is 30 mA. Rated operational voltage is 230 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1, rated impulse withstand voltage is 4 kV, and dielectric test voltage is 2 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is intended for traction applications and is declared to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 182 g.
- DS201T C20 A30
ABB DS201T C20 A30 is a two-pole (1P+N) leakage protection circuit breaker with a C tripping characteristic and Type A residual current. Rated current is 20 A, rated residual current 30 mA, rated operational voltage 230 V AC according to IEC 60898-1, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) 10 kA, and rated service short-circuit breaking capacity (Ics) 7.5 kA. It is declared to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545, and is suitable for traction applications. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 182 g. Screw terminals accept conductors from 0.75 to 25 mm², with 12 mm stripping length and 2.8 N·m tightening torque. Operating ambient temperature is -25 to 55 °C.
- DS201T C20 APR30
ABB DS201T C20 APR30 is a leakage protection circuit breaker for traction applications, with a C tripping characteristic and Type APR residual current. It carries a 20 A rated current, 30 mA rated residual current, and 6 kA rated short-circuit capacity, with 10 kA rated ultimate short-circuit breaking capacity (Icu) and 7.5 kA rated service short-circuit breaking capacity (Ics). Rated operational voltage is 230 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1; rated impulse withstand voltage is 4 kV. It has two poles, one protected, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 182 g net weight. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545.
- DS201T C25 A30
The ABB DS201T C25 A30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It is rated 25 A, 30 mA residual current, and 230 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V per IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is designed for traction applications and conforms to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. DIN-rail mounting, two module widths, 35 mm wide, 85 mm high, 69 mm deep, 182 g.
- DS201T C25 APR30
The ABB DS201T C25 APR30 is a 1P+N leakage protection circuit breaker for traction applications. It is rated 25 A with a 30 mA rated residual current and C tripping characteristic, Type APR residual current. Rated operational voltage is 230 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It mounts on DIN rail with screw terminals and a failsafe bi-directional cylinder-lift terminal. Operating ambient air temperature is -25 to 55 °C. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545.
- DS201T C32 A30
ABB DS201T C32 A30 leakage protection circuit breaker, 1P+N RCBO for single-phase circuits. Rated current 32 A, rated residual current 30 mA, Type A residual current, tripping characteristic C. Rated operational voltage 230 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV; rated frequency 50 to 60 Hz. Rated short-circuit capacity 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 182 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.