- DS201T C32 A30
ABB DS201T C32 A30 leakage protection circuit breaker, 1P+N RCBO for single-phase circuits. Rated current 32 A, rated residual current 30 mA, Type A residual current, tripping characteristic C. Rated operational voltage 230 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV; rated frequency 50 to 60 Hz. Rated short-circuit capacity 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 182 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201T C32 APR30
The ABB DS201T C32 APR30 is a leakage protection circuit breaker with a rated current of 32 A and a rated residual current of 30 mA. It has a C tripping characteristic, Type APR residual current, and is intended for traction applications. Rated operational voltage is 230 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. It has two poles, one protected pole, and DIN-rail mounting. Standards listed include IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545.
- DS201T C6 APR30
The ABB DS201T C6 APR30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type APR residual current. It has a rated current of 6 A, rated residual current of 30 mA, and rated operational voltage of 230 V AC according to IEC 60898-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is rated for 50 to 60 Hz and has a rated impulse withstand voltage of 4 kV. The device is intended for traction applications and is suitable for DIN-rail mounting. It measures 35 mm wide, 85 mm high, and 69 mm deep, with a net weight of 182 g.
- DS201T K10 A30
ABB DS201T K10 A30 is a 1P+N leakage protection circuit breaker with a K tripping characteristic and Type A residual current detection. Rated current is 10 A and rated residual current is 30 mA. It is rated 230 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It complies with IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. It is intended for traction applications and mounts on DIN rail.
- DS201T K13 A30
ABB DS201T K13 A30 is a leakage protection circuit breaker (RCBO) for traction applications, with manufacturer ID 2CSR255188R1137. It has a K tripping characteristic, Type A residual current, one protected pole, and two poles total. Ratings: 13 A rated current, 30 mA rated residual current, 230 V rated operational voltage according to IEC 60898-1, 50 to 60 Hz, 6 kA rated short-circuit capacity, 10 kA rated ultimate short-circuit breaking capacity, and 7.5 kA rated service short-circuit breaking capacity. It is declared to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. DIN-rail mounting, 35 mm wide, 85 mm high, 69 mm deep, 182 g, IP20/IP40, operating from -25 to 55 °C.
- DS201T K16 A30
The ABB DS201T K16 A30 is a leakage protection circuit breaker for traction applications. It has a rated current of 16 A, a rated residual current of 30 mA, Type A residual current, and K tripping characteristic. Rated operational voltage is 230 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. The device has two poles, one protected pole, two modular spacings, and DIN-rail mounting. It measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 182 g. Standards: IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, EN 45545.
- DS201T K20 A30
The ABB DS201T K20 A30 is a 1P+N residual current circuit breaker with overcurrent protection, identified by manufacturer ID 2CSR255188R1207. It has a rated current of 20 A, rated residual current of 30 mA, Type A residual current, and K tripping characteristic. Rated operational voltage is 230 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA. It is intended for traction applications and is suitable for DIN-rail mounting. Standards listed include IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. Dimensions are 35 mm width, 85 mm height, 69 mm depth, 182 g net weight.
- DS201T K25 A30
The ABB DS201T K25 A30 is a two-module leakage protection circuit breaker with a rated current of 25 A and a rated residual current of 30 mA. It has a K tripping characteristic and Type A residual current. Rated operational voltage is 230 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is suitable for traction applications and conforms to IEC 61009-1, IEC 61009-2-1, EN 61009-1, EN 61009-2-1, and EN 45545. Dimensions are 35 mm wide, 85 mm high, and 69 mm deep, weighing 182 g.