- DS201 C20 AC300
ABB DS201 C20 AC300 is a 1P+N residual current circuit breaker with overcurrent protection, rated 20 A and 300 mA residual current, tripping characteristic C, Type AC residual current. It is rated 240 V AC according to IEC 60898-1 and covers 50 to 60 Hz. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity Icu is 10 kA; rated service short-circuit breaking capacity Ics is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two modular spacings on DIN rail, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. Operating ambient air temperature is -25 to 55 °C. Terminal tightening torque is 2.8 N·m.
- DS201 C20 APR100
The ABB DS201 C20 APR100 is a 1P+N residual current circuit breaker with overcurrent protection, rated 20 A with a C tripping characteristic and 100 mA Type A residual current. It is rated 240 V AC according to IEC 60898-1, with a rated short-circuit capacity of 6 kA, rated ultimate short-circuit breaking capacity of 10 kA, and rated impulse withstand voltage of 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, occupies two modular spacings, and mounts on DIN rail. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with a net weight of 200 g.
- DS201 C20 APR30
ABB DS201 C20 APR30 leakage protection circuit breaker, 1P+N RCBO with one protected pole and two poles total. Rated current 20 A, rated residual current 30 mA, Type A residual current, tripping characteristic C. Rated operational voltage 240 V AC per IEC 60898-1; rated frequency 50 to 60 Hz. Rated short-circuit capacity 6 kA, rated ultimate short-circuit breaking capacity 10 kA, rated service short-circuit breaking capacity 7.5 kA. Complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 C20 APR300
ABB DS201 C20 APR300 is a 1P+N residual current circuit breaker (RCBO) combining overcurrent and earth fault protection in one device. It is rated 20 A with a 300 mA Type A residual current, C tripping characteristic, and 240 V AC rated operational voltage per IEC 60898-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated residual breaking capacity is 6000 A to EN 61009-1 and IEC 61009-1. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail module spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Screw terminals accept conductors from 0.75 to 25 mm². Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 C20 G30
ABB DS201 C20 G30 is a 1P+N leakage protection circuit breaker with a rated current of 20 A and rated residual current of 30 mA. It has a C tripping characteristic and Type A/G residual current. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is a 2-pole device with one protected pole, two modular spacings, DIN-rail mounting, screw terminals, and dimensions of 35 mm width, 85 mm height, and 69 mm depth. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 C25 A100
The ABB DS201 C25 A100 is a 1P+N residual current circuit breaker with a rated current of 25 A, rated residual current of 100 mA, and Type A residual current sensitivity. It has a C tripping characteristic and a rated ultimate short-circuit breaking capacity (Icu) of 10 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Screw terminals accept conductors from 0.75 to 25 mm². Operating ambient temperature range is -25 to 55 °C.
- DS201 C25 A30
The ABB DS201 C25 A30 is a 1P+N residual current operated circuit breaker with overcurrent protection, rated 25 A with C tripping characteristic and 30 mA Type A residual current sensitivity. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA rated ultimate short-circuit breaking capacity, and 7.5 kA rated service short-circuit breaking capacity. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The two-module DIN-rail device measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, accepts conductors from 0.75 to 25 mm², and operates from -25 to 55 °C.
- DS201 C25 A300
ABB DS201 C25 A300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 25 A, rated residual current of 300 mA, Type A residual current, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep.