- DS201 C20 G30
ABB DS201 C20 G30 is a 1P+N leakage protection circuit breaker with a rated current of 20 A and rated residual current of 30 mA. It has a C tripping characteristic and Type A/G residual current. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It is a 2-pole device with one protected pole, two modular spacings, DIN-rail mounting, screw terminals, and dimensions of 35 mm width, 85 mm height, and 69 mm depth. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 C25 A100
The ABB DS201 C25 A100 is a 1P+N residual current circuit breaker with a rated current of 25 A, rated residual current of 100 mA, and Type A residual current sensitivity. It has a C tripping characteristic and a rated ultimate short-circuit breaking capacity (Icu) of 10 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Screw terminals accept conductors from 0.75 to 25 mm². Operating ambient temperature range is -25 to 55 °C.
- DS201 C25 A30
The ABB DS201 C25 A30 is a 1P+N residual current operated circuit breaker with overcurrent protection, rated 25 A with C tripping characteristic and 30 mA Type A residual current sensitivity. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA rated ultimate short-circuit breaking capacity, and 7.5 kA rated service short-circuit breaking capacity. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The two-module DIN-rail device measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, accepts conductors from 0.75 to 25 mm², and operates from -25 to 55 °C.
- DS201 C25 A300
ABB DS201 C25 A300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 25 A, rated residual current of 300 mA, Type A residual current, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep.
- DS201 C25 AC100
ABB DS201 C25 AC100 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current detection. It is rated 25 A, 100 mA residual current, and 240 V AC according to IEC 60898-1. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA, rated service short-circuit breaking capacity (Ics) is 7.5 kA, and rated conditional short-circuit current (Inc) is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modules (35 mm wide, 85 mm high, 69 mm deep) and uses screw terminals with 2.8 N·m tightening torque. Operating ambient air temperature is -25 to 55 °C.
- DS201 C25 AC30
The ABB DS201 C25 AC30 is a 1P+N residual current circuit breaker with overcurrent protection. It has a rated current of 25 A, a rated residual current of 30 mA, Type AC residual current, and C tripping characteristic. Rated operational voltage is 240 V per IEC 60898-1, rated insulation voltage is 500 V per IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. It is a 2-pole device with one protected pole, 2 modular spacings, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, and 69 mm depth. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Operating ambient air temperature is -25 to 55 °C.
- DS201 C25 AC300
ABB DS201 C25 AC300 is a 1P+N residual current circuit breaker (RCBO) with a C tripping characteristic and Type AC residual current detection. Rated current is 25 A and rated residual current is 300 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 C25 APR100
ABB DS201 C25 APR100 is a 1P+N residual current operated circuit breaker with overcurrent protection, rated 25 A, tripping characteristic C, Type A residual current, rated residual current 100 mA. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated short-circuit capacity 6 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, occupies two DIN-rail modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Operating ambient air temperature is -25 to 55 degrees C. Contact position is indicated red ON and green OFF, with a blue flag on the toggle for fault indication.