- DS201 C25 A30
The ABB DS201 C25 A30 is a 1P+N residual current operated circuit breaker with overcurrent protection, rated 25 A with C tripping characteristic and 30 mA Type A residual current sensitivity. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated frequency 50 to 60 Hz. Short-circuit ratings include 6 kA rated short-circuit capacity, 10 kA rated ultimate short-circuit breaking capacity, and 7.5 kA rated service short-circuit breaking capacity. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The two-module DIN-rail device measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, accepts conductors from 0.75 to 25 mm², and operates from -25 to 55 °C.
- DS201 C25 A300
ABB DS201 C25 A300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 25 A, rated residual current of 300 mA, Type A residual current, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep.
- DS201 C25 AC100
ABB DS201 C25 AC100 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current detection. It is rated 25 A, 100 mA residual current, and 240 V AC according to IEC 60898-1. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity (Icu) is 10 kA, rated service short-circuit breaking capacity (Ics) is 7.5 kA, and rated conditional short-circuit current (Inc) is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two DIN-rail modules (35 mm wide, 85 mm high, 69 mm deep) and uses screw terminals with 2.8 N·m tightening torque. Operating ambient air temperature is -25 to 55 °C.
- DS201 C25 AC30
The ABB DS201 C25 AC30 is a 1P+N residual current circuit breaker with overcurrent protection. It has a rated current of 25 A, a rated residual current of 30 mA, Type AC residual current, and C tripping characteristic. Rated operational voltage is 240 V per IEC 60898-1, rated insulation voltage is 500 V per IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 6 kA; rated ultimate short-circuit breaking capacity is 10 kA. It is a 2-pole device with one protected pole, 2 modular spacings, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, and 69 mm depth. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Operating ambient air temperature is -25 to 55 °C.
- DS201 C25 AC300
ABB DS201 C25 AC300 is a 1P+N residual current circuit breaker (RCBO) with a C tripping characteristic and Type AC residual current detection. Rated current is 25 A and rated residual current is 300 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity is 10 kA, and rated service short-circuit breaking capacity is 7.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 C25 APR100
ABB DS201 C25 APR100 is a 1P+N residual current operated circuit breaker with overcurrent protection, rated 25 A, tripping characteristic C, Type A residual current, rated residual current 100 mA. It is rated 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1, rated impulse withstand voltage 4 kV, and rated short-circuit capacity 6 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, occupies two DIN-rail modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep, weighing 200 g. Operating ambient air temperature is -25 to 55 degrees C. Contact position is indicated red ON and green OFF, with a blue flag on the toggle for fault indication.
- DS201 C25 APR30
ABB DS201 C25 APR30 is a DIN-rail leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It is rated 25 A, 30 mA, 240 V AC, 50 to 60 Hz, with rated impulse withstand voltage 4 kV and overvoltage category III. Rated ultimate short-circuit breaking capacity Icu is 10 kA; rated service short-circuit breaking capacity Ics is 7.5 kA; rated short-circuit capacity is 6 kA. It has two poles, one protected pole, 2 modular spacings, and screw terminals with 2.8 N·m tightening torque. Contact position indication is red ON / green OFF, with a blue fault-indication flag on the toggle. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1.
- DS201 C25 APR300
The ABB DS201 C25 APR300 is a 1P+N residual current circuit breaker with overcurrent protection, identified by manufacturer ID 2CSR255480R3254. It has a rated current of 25 A, rated residual current of 300 mA, Type A residual current, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V per IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It is rated 6 kA conditional short-circuit current and 10 kA ultimate short-circuit breaking capacity. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, is 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.