- ESB16-02N-07
ABB ESB16-02N-07 building contactor, manufacturer ID 1SBE111111R0702. Two-pole device with two main contacts, both normally closed, and no auxiliary contacts. Rated operational voltage is 220 V DC and 250 V AC for the main circuit; rated control circuit voltage is 400 V. Rated operational current AC-1 (NC) is 16 A, AC-3 at 230 V single-phase (NC) is 6 A, AC-7a (NC) is 16 A, and AC-7b at 230 V single-phase (NC) is 6 A. Rated insulation voltage is 400 V and rated impulse withstand voltage is 6 kV. Dimensions are 18 mm wide, 85 mm high, and 65 mm deep; net weight 0.14 kg. Degree of protection IP20, pollution degree 3, maximum operating altitude 2000 m. Ambient air temperature: operation -25 to +55 °C, storage -40 to +80 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB16-02N-14
ABB ESB16-02N-14 building contactor with manufacturer ID 1SBE111111M1402. Two poles, two main contacts NC, no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage 12 V; rated frequency includes control circuit DC, 50 Hz, 60 Hz, 400 Hz and main circuit DC, 50 Hz, 60 Hz. Rated operational current AC-1 (NC) 16 A; AC-3 (230 V) single phase, NC 6 A. Rated insulation voltage 400 V; rated impulse withstand voltage 6 kV. Dimensions 18 mm width, 85 mm height, 65 mm depth; net weight 0.14 kg. IP20, pollution degree 3. Mechanical durability 1,000,000 cycles; electrical durability 150,000 cycles at AC-1, AC-3, AC-7a and AC-7b. Ambient air temperature operation -25 to +55 °C, storage -40 to +80 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB16-11N-01
ABB ESB16-11N-01 building contactor, 2-pole with one normally open and one normally closed main contact. Rated operational current is 16 A AC-1 and AC-7a, and 6 A AC-3 and AC-7b at 230 V single phase. Rated operational voltage is 220 V DC or 250 V AC main circuit; rated control circuit voltage is 24 V. Rated insulation voltage is 400 V and rated impulse withstand voltage is 6 kV. Dimensions are 18 mm wide, 85 mm high, and 65 mm deep, weighing 0.14 kg. Degree of protection is IP20. Ambient air temperature range is -25 to +55 °C in operation. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, and IEC 60335-2-40 A2L.
- ESB16-11N-02
The ABB ESB16-11N-02 is a two-pole building contactor with one normally open and one normally closed main contact, rated 16 A at AC-1 and AC-7a. Rated operational voltage is 220 V DC or 250 V AC on the main circuit; rated control circuit voltage is 42 V. Rated operational current AC-3 is 6 A at 230 V single phase, with rated operational power AC-3 of 0.9 kW at 230 V single phase. Rated insulation voltage is 400 V and rated impulse withstand voltage is 6 kV. Dimensions are 18 mm wide, 85 mm high, and 65 mm deep, weight 0.14 kg, degree of protection IP20. Mechanical durability is 1,000,000 cycles; electrical durability is 150,000 cycles for AC-1, AC-3, AC-7a, and AC-7b. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB16-11N-04
ABB building contactor ESB16-11N-04 (manufacturer ID 1SBE111111M0411) is a 2-pole installation contactor with one normally open and one normally closed main contact, rated 16 A at AC-1 and AC-7a. Rated operational voltage is 220 V DC or 250 V AC on the main circuit; rated control circuit voltage is 110 V. Rated operational current at AC-3 is 6 A single phase at 230 V, corresponding to 0.9 kW; AC-1 and AC-7a power is 3.7 kW at 230 V. Rated insulation voltage is 400 V and rated impulse withstand voltage is 6 kV. Dimensions are 18 mm wide, 85 mm high, and 65 mm deep, with 0.14 kg net weight. Degree of protection is IP20, pollution degree 3, and operating ambient air temperature range is -25 to +55 degrees C.
- ESB16-11N-05
ABB building contactor ESB16-11N-05, manufacturer ID 1SBE111111M0511, two-pole installation contactor for distribution boards. Main contacts: 1 NO and 1 NC. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage (Uc) 240 V. Rated operational current AC-1 (Ie) 16 A for NO and NC; AC-3 (Ie) 6 A at 230 V single phase for NO and NC. Rated operational power AC-1 (Pe) 3.7 kW at 230 V single phase; AC-3 (Pe) 0.9 kW at 230 V single phase. Rated impulse withstand voltage (Uimp) 6 kV; rated insulation voltage (Ui) 400 V. Degree of protection IP20. Dimensions 18 mm wide, 85 mm high, 65 mm deep; net weight 0.14 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB16-11N-06
ABB building contactor ESB16-11N-06, 2-pole with one normally open and one normally closed main contact. Rated operational current is 16 A at AC-1 and AC-7a, and 6 A at AC-3 and AC-7b at 230 V single phase. Rated operational power is 3.7 kW at AC-1 and AC-7a, and 0.9 kW at AC-3 and AC-7b at 230 V single phase. Main circuit rated operational voltage is 220 V DC or 250 V AC; rated control circuit voltage is 230 V. Rated impulse withstand voltage is 6 kV, rated insulation voltage 400 V. Dimensions are 18 mm wide, 85 mm high, and 65 mm deep, weighing 0.14 kg. Degree of protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, and IEC 60335-2-40 A2L.
- ESB16-11N-14
ABB building contactor ESB16-11N-14, manufacturer ID 1SBE111111R1411. Two-pole device with one normally open and one normally closed main contact, no auxiliary contacts. Rated operational current 16 A at AC-1 and AC-7a for both NO and NC contacts; 6 A at AC-3 and AC-7b at 230 V single phase. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage 12 V. Rated insulation voltage 400 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 18 mm wide, 85 mm high, 65 mm deep; net weight 0.14 kg. IP20. Mechanical durability 1,000,000 cycles; electrical durability 150,000 cycles for AC-1, AC-3, AC-7a, and AC-7b. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.