Industrial Automation Parts. Prompt replies from real people.

ABB ESB16-02N-07 Installation Contactors

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB ESB16-02N-07?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB ESB16-02N-07 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
ESB16-02N-07
Material Number
1SBE111111R0702
Manufacturer
ABB
Product ID
81557

Get a Free Quote

Request pricing and availability for ESB16-02N-07.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.14 kg
Rated Operational Voltage
Main Circuit 220 V DC Main Circuit 250 V AC
Rated Control Circuit Voltage (Uc)
400 V
Rated Frequency (f)
Control Circuit DC Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit 400 Hz Main Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)
(NC) 16 A
Rated Operational Power AC-1 (Pe)
(230 V) Single Phase, NC 3.7 kW
See all specifications

Product Highlights

  1. Rated Operational Voltage: Main circuit 220 V DC or 250 V AC
  2. Contact Configuration: 2 NC main contacts with no NO main contacts or auxiliary contacts
  3. Current and Power Ratings: 16 A AC-1 and AC-7a, 6 A AC-3 and AC-7b at 230 V single phase, with 3.7 kW AC-1/AC-7a and 0.9 kW AC-3/AC-7b
  4. Durability: 150000 electrical cycles for AC-1, AC-3, AC-7a, and AC-7b, and 1000000 mechanical cycles
  5. Compact Dimensions: 18 mm width, 85 mm height, 65 mm depth, 0.14 kg weight, and 1.0 modular spacing
ESB16-02N-07

Product Information

Technical Specifications

Specifications for ESB16-02N-07

ParameterValue
Product Net Width18 mm
Product Net Height85 mm
Product Net Depth / Length65 mm
Product Net Weight0.14 kg
Rated Operational VoltageMain Circuit 220 V DC Main Circuit 250 V AC
Rated Control Circuit Voltage (Uc)400 V
Rated Frequency (f)Control Circuit DC Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit 400 Hz Main Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)(NC) 16 A
Rated Operational Current AC-3 (Ie)(230 V) Single Phase, NC 6 A
Rated Operational Power AC-1 (Pe)(230 V) Single Phase, NC 3.7 kW
Rated Operational Power AC-3 (Pe)(230 V) Single Phase, NC 0.9 kW
Rated Operational Current AC-7a (Ie)(NC) 16 A
Rated Operational Power AC-7a (Pe)(230 V) Single Phase, NC 3.7 kW
Rated Operational Current AC-7b (Ie)(230 V) Single Phase, NC 6 A
Rated Operational Power AC-7b (Pe)(230 V) Single Phase, NC 0.9 kW
Recommended Screw DriverControl Circuit Pozidriv 1 Main Circuit Pozidriv 1
Rated Impulse Withstand Voltage (Uimp)6 kV
Rated Insulation Voltage (Ui)400 V
Connecting Capacity Main CircuitFlexible with Ferrule 1x 1 ... 6 mm² Flexible with Ferrule 2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1x 1 ... 6 mm² Flexible with Insulated Ferrule 2x 1 ... 1.5 mm² Flexible 1x 1 ... 6 mm² Flexible 2x 1 ... 4 mm² Rigid 1x 1 ... 10 mm² Rigid 2x 1 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 1 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 1 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² Flexible 1x 1 ... 2.5 mm² Flexible 2x 1 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.75 ... 2.5 mm²
Tightening TorqueControl Circuit 0.9 N·m Main Circuit 1.2 N·m
Wire Stripping LengthControl Circuit 7 mm Main Circuit 10 mm
Degree of ProtectionIP20
ParameterValue
Electrical DurabilityAC-1 (NC) 150000 cycle AC-3 (NC) 150000 cycle AC-7a (NC) 150000 cycle AC-7b (NC) 150000 cycle
Mechanical Durability1000000 cycle
Number of Poles2
Number of Auxiliary Contacts NC0
Number of Auxiliary Contacts NO0
Number of Main Contacts NC2
Number of Main Contacts NO0
Width in Number of Modular Spacings1.0
Pollution Degree3
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC/EN 61095 IEC 60335-2-40 A2L
Maximum Operating Voltage UL/CSAMain Circuit 240 V AC
Horsepower Rating UL/CSA(220 ... 240 V AC) Single Phase, NC 0.75 Hp
Connecting Capacity Main Circuit UL/CSASolid 14-8 AWG Stranded 14-8 AWG
Connecting Capacity Control Circuit UL/CSASolid 16-10 AWG Stranded 16-10 AWG
Tightening Torque UL/CSAControl Circuit 8 in·lb Main Circuit 11 in·lb
Ambient Air TemperatureOperation -25 ... +55 °C Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Object Classification CodeQ
ETIM 5EC001653 - Installation contactor for distribution board
ETIM 6EC001653 - Installation contactor for distribution board
ETIM 7EC001653 - Installation contactor for distribution board
eClassV11.0 : 27142308
UNSPSC39121529
IDEA Granular Category Code (IGCC)4759 >> Installation contactor for distribution board
ETIM 8EC001653 - Installation contactor for distribution board
Manufacturer ID1SBE111111R0702

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp