- ESB16-11N-05
ABB building contactor ESB16-11N-05, manufacturer ID 1SBE111111M0511, two-pole installation contactor for distribution boards. Main contacts: 1 NO and 1 NC. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage (Uc) 240 V. Rated operational current AC-1 (Ie) 16 A for NO and NC; AC-3 (Ie) 6 A at 230 V single phase for NO and NC. Rated operational power AC-1 (Pe) 3.7 kW at 230 V single phase; AC-3 (Pe) 0.9 kW at 230 V single phase. Rated impulse withstand voltage (Uimp) 6 kV; rated insulation voltage (Ui) 400 V. Degree of protection IP20. Dimensions 18 mm wide, 85 mm high, 65 mm deep; net weight 0.14 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB16-11N-06
ABB building contactor ESB16-11N-06, 2-pole with one normally open and one normally closed main contact. Rated operational current is 16 A at AC-1 and AC-7a, and 6 A at AC-3 and AC-7b at 230 V single phase. Rated operational power is 3.7 kW at AC-1 and AC-7a, and 0.9 kW at AC-3 and AC-7b at 230 V single phase. Main circuit rated operational voltage is 220 V DC or 250 V AC; rated control circuit voltage is 230 V. Rated impulse withstand voltage is 6 kV, rated insulation voltage 400 V. Dimensions are 18 mm wide, 85 mm high, and 65 mm deep, weighing 0.14 kg. Degree of protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, and IEC 60335-2-40 A2L.
- ESB16-11N-14
ABB building contactor ESB16-11N-14, manufacturer ID 1SBE111111R1411. Two-pole device with one normally open and one normally closed main contact, no auxiliary contacts. Rated operational current 16 A at AC-1 and AC-7a for both NO and NC contacts; 6 A at AC-3 and AC-7b at 230 V single phase. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage 12 V. Rated insulation voltage 400 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 18 mm wide, 85 mm high, 65 mm deep; net weight 0.14 kg. IP20. Mechanical durability 1,000,000 cycles; electrical durability 150,000 cycles for AC-1, AC-3, AC-7a, and AC-7b. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB16-20N-01
The ABB ESB16-20N-01 is a two-pole building contactor with two normally open main contacts and no auxiliary contacts. It measures 18 mm wide, 85 mm high, and 65 mm deep, and weighs 0.14 kg. The main circuit is rated 220 V DC and 250 V AC; the control circuit is rated 24 V. Rated operational current is 16 A at AC-1 and AC-7a, and 6 A at AC-3 and AC-7b at 230 V single phase. Rated insulation voltage is 400 V and rated impulse withstand voltage is 6 kV. Degree of protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, and IEC 60335-2-40 A2L.
- ESB16-20N-02
The ABB ESB16-20N-02 is a two-pole building contactor with two normally open main contacts and no auxiliary contacts. Rated operational current is 16 A at AC-1 and AC-7a, and 6 A at AC-3 and AC-7b at 230 V single phase. Rated operational voltage is 220 V DC or 250 V AC in the main circuit, with a rated control circuit voltage of 42 V. Dimensions are 18 mm wide, 85 mm high, and 65 mm deep, with a net weight of 0.14 kg. It offers IP20 degree of protection, 6 kV rated impulse withstand voltage, 400 V rated insulation voltage, and operates from -25 to +55 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, and IEC/EN 61095.
- ESB16-20N-04
The ABB ESB16-20N-04 is a 2-pole building contactor with two normally open main contacts and no auxiliary contacts. It measures 18 mm wide, 85 mm high, and 65 mm deep, and weighs 0.14 kg. The main circuit is rated 220 V DC and 250 V AC, with a rated insulation voltage of 400 V and a rated impulse withstand voltage of 6 kV. Rated operational current is 16 A in AC-1 and AC-7a, and 6 A in AC-3 and AC-7b at 230 V single-phase. The control circuit is rated 110 V. Electrical durability is 150000 cycles; mechanical durability is 1000000 cycles. Degree of protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, and IEC/EN 61095.
- ESB16-20N-05
ABB building contactor ESB16-20N-05, manufacturer ID 1SBE111111R0520. Two-pole installation contactor with two normally open main contacts, no auxiliary contacts. Rated operational current AC-1 (NO) 16 A; AC-3 (230 V) single phase, NO 6 A; AC-7a (NO) 16 A; AC-7b (230 V) single phase, NO 6 A. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage (Uc) 240 V. Rated insulation voltage (Ui) 400 V; rated impulse withstand voltage (Uimp) 6 kV. Dimensions 18 mm wide, 85 mm high, 65 mm deep; net weight 0.14 kg. Degree of protection IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.
- ESB16-20N-06
ABB building contactor ESB16-20N-06, manufacturer ID 1SBE111111R0620. Two-pole installation contactor with two normally open main contacts and no auxiliary contacts. Rated operational voltage: main circuit 220 V DC and 250 V AC. Rated control circuit voltage 230 V. Rated operational current: AC-1 16 A; AC-3 6 A at 230 V single-phase; AC-7a 16 A; AC-7b 6 A at 230 V single-phase. Rated operational power: AC-1 3.7 kW, AC-3 0.9 kW, AC-7a 3.7 kW, AC-7b 0.9 kW at 230 V single-phase. Rated insulation voltage 400 V; rated impulse withstand voltage 6 kV. Dimensions 18 x 85 x 65 mm, 0.14 kg. IP20, pollution degree 3. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L.