- DS201 M C10 APR300
ABB DS201 M C10 APR300 is a 1P+N leakage protection circuit breaker with a rated current of 10 A and rated residual current of 300 mA, Type A. It has a C tripping characteristic and an instantaneous APR high-immunity operating characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is a two-pole device with one protected pole, two modular spacings, DIN-rail mounting, screw terminals, 35 mm net width, 85 mm net height, 69 mm net depth, and 200 g net weight. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C10 F10
ABB DS201 M C10 F10 leakage protection circuit breaker, 2CSR275580R0104. Rated current 10 A, rated residual current 10 mA, Type F residual current, C tripping characteristic. Rated short-circuit capacity 10 kA; rated ultimate short-circuit breaking capacity (Icu) 15 kA; rated service short-circuit breaking capacity (Ics) 11.2 kA. Rated operational voltage according to IEC 60898-1 240 V AC, 50 to 60 Hz. Rated impulse withstand voltage (Uimp) 4 kV. Two poles, one protected pole, two modular spacings, DIN-rail mounting, screw terminals, tightening torque 2.8 N·m. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1. Dimensions 35 mm width, 85 mm height, 69 mm depth; net weight 200 g. Operating ambient air temperature -25 to 55 °C.
- DS201 M C10 F30
ABB DS201 M C10 F30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type F residual current. It has a rated current of 10 A and a rated residual current of 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage is 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is a two-module DIN-rail device, 35 mm wide, 85 mm high, and 69 mm deep, with screw terminals and 2.8 N·m tightening torque. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C10 G30
ABB DS201 M C10 G30 leakage protection circuit breaker, 1P+N, DIN-rail mounting. Rated current 10 A with C tripping characteristic; rated residual current 30 mA, Type A/G. Rated operational voltage 230 V AC per IEC 60898-1; rated insulation voltage 500 V per IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity (Icu) 15 kA, rated service short-circuit breaking capacity (Ics) 11.2 kA. Rated frequency 50 to 60 Hz. Screw terminals accept rigid 0.75 to 25 mm² and flexible 0.75 to 16 mm² conductors; tightening torque 1.2 N·m. Toggle actuator with red ON / green OFF contact position indication and blue fault flag. Two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. Ambient air temperature -25 to 55 °C; IP20.
- DS201 M C13 A30
The ABB DS201 M C13 A30 is a 1P+N residual current circuit breaker with overcurrent protection, rated 13 A and 30 mA Type A residual current sensitivity. Tripping characteristic is C. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. It has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight is 200 g.
- DS201 M C13 A30 110V
The ABB DS201 M C13 A30 110V is a 1P+N leakage protection circuit breaker (RCBO) with a C tripping characteristic and Type A residual current detection. Rated current is 13 A; rated residual current is 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, and the test voltage is 110 V. It is rated 50 to 60 Hz with a rated short-circuit capacity of 10 kA and rated ultimate short-circuit breaking capacity (Icu) of 15 kA. Standards: IEC 61009-1 and IEC 61009-2-1. It has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Dimensions are 35 mm wide, 85 mm high, and 69 mm deep; net weight is 200 g.
- DS201 M C13 A300
ABB DS201 M C13 A300 is a 1P+N leakage protection circuit breaker (RCBO) with a C tripping characteristic and Type A residual current. It carries a 13 A rated current, 300 mA rated residual current, and 240 V rated operational voltage according to IEC 60898-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) 15 kA, and rated service short-circuit breaking capacity (Ics) 11.2 kA. It is rated 50 to 60 Hz and complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, 2 modular spacings, DIN-rail mounting, screw terminals, 2.8 N·m tightening torque, and dimensions 35 mm width, 85 mm height, 69 mm depth.
- DS201 M C13 AC100
The ABB DS201 M C13 AC100 is a leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It is rated 13 A with a rated residual current of 100 mA, rated operational voltage according to IEC 60898-1 of 240 V, and rated frequency of 50 to 60 Hz. It provides a rated short-circuit capacity of 10 kA and a rated ultimate short-circuit breaking capacity (Icu) of 15 kA. The device has one protected pole, two poles total, and occupies two modular spacings on DIN rail. It measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1.