- DS201 M C13 AC30
ABB DS201 M C13 AC30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. Rated current is 13 A with a rated residual current of 30 mA. Rated operational voltage is 240 V AC per IEC 60898-1; rated insulation voltage is 500 V per IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight.
- DS201 M C13 AC300
ABB DS201 M C13 AC300 is a leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It is a 1P+N device with one protected pole, rated current 13 A, rated residual current 300 mA, and rated operational voltage 240 V AC according to IEC 60898-1. It is rated 50 to 60 Hz and has a rated short-circuit capacity of 10 kA, rated ultimate short-circuit breaking capacity (Icu) of 15 kA, and rated service short-circuit breaking capacity (Ics) of 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals accept 0.75 to 25 mm² conductors; tightening torque is 2.8 N·m. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 M C13 APR100
The ABB DS201 M C13 APR100 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 13 A and a C tripping characteristic. It provides Type A residual current protection with a rated residual current of 100 mA and an instantaneous APR high-immunity operating characteristic. Rated short-circuit capacity is 10 kA, with rated ultimate short-circuit breaking capacity (Icu) of 15 kA and rated service short-circuit breaking capacity (Ics) of 11.2 kA. It is rated 240 V AC according to IEC 60898-1 and 50 to 60 Hz, and conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The two-module DIN-rail device measures 35 mm wide, 85 mm high, and 69 mm deep, and operates from -25 to 55 degrees C.
- DS201 M C13 APR30
The ABB DS201 M C13 APR30 is a leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 30 mA, Type A. It has a C tripping characteristic and one protected pole in a two-pole device. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Mounting is DIN rail, width 35 mm, height 85 mm, depth 69 mm, weight 200 g.
- DS201 M C13 APR300
The ABB DS201 M C13 APR300 is a leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 300 mA, Type A. It has a C tripping characteristic and an instantaneous APR high-immunity operating characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated frequency of 50 to 60 Hz. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It provides one protected pole in a two-pole, two-modular-spacing DIN-rail housing measuring 35 mm wide, 85 mm high, and 69 mm deep. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C13 F10
ABB DS201 M C13 F10 leakage protection circuit breaker, manufacturer ID 2CSR275580R0134. It is a 1P+N RCBO with one protected pole and two poles, rated current 13 A, C tripping characteristic, Type F residual current, and rated residual current 10 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency 50 to 60 Hz. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Ambient air temperature -25 to 55 °C.
- DS201 M C13 F30
The ABB DS201 M C13 F30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type F residual current sensitivity of 30 mA. It is rated 13 A at 240 V AC, 50 to 60 Hz, with a rated short-circuit capacity of 10 kA and rated ultimate short-circuit breaking capacity (Icu) of 15 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected, occupies two DIN-rail modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Screw terminals accept conductors from 0.75 to 25 mm², with 2.8 N·m tightening torque. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20 and IP40.
- DS201 M C13 G30
ABB DS201 M C13 G30 is a 1P+N leakage protection circuit breaker (RCBO) with C tripping characteristic, 13 A rated current, and 30 mA rated residual current, Type A/G. Rated operational voltage is 240 V AC according to IEC 60898-1; rated impulse withstand voltage is 4 kV, rated insulation voltage 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. Two poles, one protected pole, two modular spacings, DIN-rail mounting, screw terminals, tightening torque 2.8 N·m. Operating ambient air temperature -25 to 55 °C. Dimensions 35 x 85 x 69 mm; weight 200 g.