- DS201 M C13 AC100
The ABB DS201 M C13 AC100 is a leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It is rated 13 A with a rated residual current of 100 mA, rated operational voltage according to IEC 60898-1 of 240 V, and rated frequency of 50 to 60 Hz. It provides a rated short-circuit capacity of 10 kA and a rated ultimate short-circuit breaking capacity (Icu) of 15 kA. The device has one protected pole, two poles total, and occupies two modular spacings on DIN rail. It measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C13 AC30
ABB DS201 M C13 AC30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. Rated current is 13 A with a rated residual current of 30 mA. Rated operational voltage is 240 V AC per IEC 60898-1; rated insulation voltage is 500 V per IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight.
- DS201 M C13 AC300
ABB DS201 M C13 AC300 is a leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It is a 1P+N device with one protected pole, rated current 13 A, rated residual current 300 mA, and rated operational voltage 240 V AC according to IEC 60898-1. It is rated 50 to 60 Hz and has a rated short-circuit capacity of 10 kA, rated ultimate short-circuit breaking capacity (Icu) of 15 kA, and rated service short-circuit breaking capacity (Ics) of 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals accept 0.75 to 25 mm² conductors; tightening torque is 2.8 N·m. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 M C13 APR100
The ABB DS201 M C13 APR100 is a 1P+N leakage protection circuit breaker (RCBO) with a rated current of 13 A and a C tripping characteristic. It provides Type A residual current protection with a rated residual current of 100 mA and an instantaneous APR high-immunity operating characteristic. Rated short-circuit capacity is 10 kA, with rated ultimate short-circuit breaking capacity (Icu) of 15 kA and rated service short-circuit breaking capacity (Ics) of 11.2 kA. It is rated 240 V AC according to IEC 60898-1 and 50 to 60 Hz, and conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The two-module DIN-rail device measures 35 mm wide, 85 mm high, and 69 mm deep, and operates from -25 to 55 degrees C.
- DS201 M C13 APR30
The ABB DS201 M C13 APR30 is a leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 30 mA, Type A. It has a C tripping characteristic and one protected pole in a two-pole device. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Mounting is DIN rail, width 35 mm, height 85 mm, depth 69 mm, weight 200 g.
- DS201 M C13 APR300
The ABB DS201 M C13 APR300 is a leakage protection circuit breaker with a rated current of 13 A and a rated residual current of 300 mA, Type A. It has a C tripping characteristic and an instantaneous APR high-immunity operating characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated frequency of 50 to 60 Hz. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It provides one protected pole in a two-pole, two-modular-spacing DIN-rail housing measuring 35 mm wide, 85 mm high, and 69 mm deep. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M C13 F10
ABB DS201 M C13 F10 leakage protection circuit breaker, manufacturer ID 2CSR275580R0134. It is a 1P+N RCBO with one protected pole and two poles, rated current 13 A, C tripping characteristic, Type F residual current, and rated residual current 10 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency 50 to 60 Hz. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Ambient air temperature -25 to 55 °C.
- DS201 M C13 F30
The ABB DS201 M C13 F30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type F residual current sensitivity of 30 mA. It is rated 13 A at 240 V AC, 50 to 60 Hz, with a rated short-circuit capacity of 10 kA and rated ultimate short-circuit breaking capacity (Icu) of 15 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected, occupies two DIN-rail modular spacings, and measures 35 mm wide, 85 mm high, and 69 mm deep. Screw terminals accept conductors from 0.75 to 25 mm², with 2.8 N·m tightening torque. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20 and IP40.