- VBC6A-30-10-F-01
ABB VBC6A-30-10-F-01 invertible contactor, manufacturer ID GJL1213913R0101. Three-pole device with three main NO contacts and one auxiliary NO contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Conventional free-air thermal current (Ith) is 20 A. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.345 kg. DIN rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VBC6A-30-10-P-01
ABB invertible contactor VBC6A-30-10-P-01, manufacturer ID GJL1213919R0101. Three-pole device with three main contacts NO, no main contacts NC, and one auxiliary contact NO. Control circuit voltage is 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC main circuit, and 250 V DC auxiliary circuit. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, 2.2 kW at 230 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg. Mechanical durability is 10,000,000 cycles. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- VBC6A-30-10-P-2.4
ABB invertible contactor VBC6A-30-10-P-2.4, manufacturer ID GJL1213919R5101. Three-pole device with three NO main contacts, one NO auxiliary contact, and no NC contacts. Main circuit rated operational voltage 690 V AC or 220 V DC; auxiliary circuit 690 V AC or 250 V DC. Rated control circuit voltage 17 to 32 V DC, with coil operating limits 0.85 to 1.1 x Uc for DC supply at ambient temperature up to 55 °C per IEC 60947-4-1. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions 96.2 x 57.5 x 47.7 mm, 0.345 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L. No CA6 or CAF6 mountable.
- VBC7-30-01-01
ABB VBC7-30-01-01 invertible contactor, manufacturer ID GJL1313901R0011. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated control circuit voltage is 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC, rated impulse withstand voltage 6 kV, rated insulation voltage 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Mechanical durability is 10,000,000 cycles. Dimensions 96.2 x 57.5 x 46.7 mm; weight 0.355 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VBC7-30-01-02
The ABB VBC7-30-01-02 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The coil is rated 42 V DC, with operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Mechanical durability is 10,000,000 cycles.
- VBC7-30-01-04
The ABB VBC7-30-01-04 is a 3-pole invertible contactor with 3 NO main contacts and 1 NC auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is rated 110 to 125 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VBC7-30-01-05
ABB VBC7-30-01-05 invertible contactor, manufacturer ID GJL1313901R0015. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Control circuit voltage 220 to 240 V DC, coil operating limits 0.85 to 1.1 x Uc at temperatures up to 55 °C per IEC 60947-4-1. Dimensions 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. DIN-rail mounting per IEC 60715 on TH35-15 or TH35-7.5 rail. Main circuit terminals IP20. Mechanical durability 10,000,000 cycles. Ambient operating temperature -20 to +55 °C.
- VBC7-30-01-07
ABB VBC7-30-01-07 invertible contactor, manufacturer ID GJL1313901R0017. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 12 V DC, coil operating limits 0.85 to 1.1 x Uc for DC supply at ambient temperature up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V and 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 96.2 x 57.5 x 46.7 mm, 0.355 kg. Screw terminals, IP20 main circuit terminals. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.