- VBC7-30-01-04
The ABB VBC7-30-01-04 is a 3-pole invertible contactor with 3 NO main contacts and 1 NC auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is rated 110 to 125 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- VBC7-30-01-05
ABB VBC7-30-01-05 invertible contactor, manufacturer ID GJL1313901R0015. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated operational power AC-3: 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Control circuit voltage 220 to 240 V DC, coil operating limits 0.85 to 1.1 x Uc at temperatures up to 55 °C per IEC 60947-4-1. Dimensions 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. DIN-rail mounting per IEC 60715 on TH35-15 or TH35-7.5 rail. Main circuit terminals IP20. Mechanical durability 10,000,000 cycles. Ambient operating temperature -20 to +55 °C.
- VBC7-30-01-07
ABB VBC7-30-01-07 invertible contactor, manufacturer ID GJL1313901R0017. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 12 V DC, coil operating limits 0.85 to 1.1 x Uc for DC supply at ambient temperature up to 55 °C. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C (220/240 V and 380/440 V); 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 96.2 x 57.5 x 46.7 mm, 0.355 kg. Screw terminals, IP20 main circuit terminals. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VBC7-30-01-16
ABB VBC7-30-01-16 invertible contactor, manufacturer ID GJL1313901R1016. Three-pole device with three main NO contacts and one auxiliary NC contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage is 48 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions: 96.2 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.355 kg.
- VBC7-30-01-F-01
The ABB VBC7-30-01-F-01 is an invertible contactor with three main NO contacts and one auxiliary NC contact. Its coil is rated 24 V DC, with operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, and 5.5 kW at 500 V three-phase. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight is 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Mechanical durability is 10,000,000 cycles. Main circuit terminals are IP20.
- VBC7-30-01-F-05
The ABB VBC7-30-01-F-05 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. Its control circuit is rated 220 to 240 V DC, and the main circuit is rated 690 V AC with a 6 kV impulse withstand voltage. Rated operational power in AC-3 is 3 kW at 230 V three-phase and 5.5 kW at 400 V and 500 V three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and operates from -20 to +55 degrees C. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VBC7-30-01-P-01
The ABB VBC7-30-01-P-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. The coil is rated 24 V DC, with operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV, and mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth, with a net weight of 0.345 kg.
- VBC7-30-10-01
ABB VBC7-30-10-01 invertible contactor with three main NO contacts, one auxiliary NO contact, and no NC contacts. Rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 96.2 mm W x 57.5 mm H x 46.7 mm D; net weight 0.355 kg. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.