- VBC7-30-01-16
ABB VBC7-30-01-16 invertible contactor, manufacturer ID GJL1313901R1016. Three-pole device with three main NO contacts and one auxiliary NC contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage is 48 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions: 96.2 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.355 kg.
- VBC7-30-01-F-01
The ABB VBC7-30-01-F-01 is an invertible contactor with three main NO contacts and one auxiliary NC contact. Its coil is rated 24 V DC, with operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C, per IEC 60947-4-1. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, and 5.5 kW at 500 V three-phase. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight is 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Mechanical durability is 10,000,000 cycles. Main circuit terminals are IP20.
- VBC7-30-01-F-05
The ABB VBC7-30-01-F-05 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. Its control circuit is rated 220 to 240 V DC, and the main circuit is rated 690 V AC with a 6 kV impulse withstand voltage. Rated operational power in AC-3 is 3 kW at 230 V three-phase and 5.5 kW at 400 V and 500 V three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.345 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 and operates from -20 to +55 degrees C. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VBC7-30-01-P-01
The ABB VBC7-30-01-P-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. The coil is rated 24 V DC, with operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 230 V and 690 V. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV, and mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth, with a net weight of 0.345 kg.
- VBC7-30-10-01
ABB VBC7-30-10-01 invertible contactor with three main NO contacts, one auxiliary NO contact, and no NC contacts. Rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 96.2 mm W x 57.5 mm H x 46.7 mm D; net weight 0.355 kg. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VBC7-30-10-04
The ABB VBC7-30-10-04 is a 3-pole invertible contactor with three NO main contacts and one NO auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The rated control circuit voltage is 110 to 125 V DC, with coil operating limits of 0.85 to 1.1 x Uc at temperatures up to 55 °C per IEC 60947-4-1. Rated operational power in AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Mechanical durability is 10,000,000 cycles. Main circuit terminals are IP20. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 60947-5-1.
- VBC7-30-10-05
ABB VBC7-30-10-05 invertible contactor, manufacturer ID GJL1313901R0105. Three-pole device with three normally open main contacts and one normally open auxiliary contact. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, and 5.5 kW at 500 V three-phase. Rated control circuit voltage is 220 to 240 V DC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1 for DC supply at ambient temperatures up to 55 degrees C. Dimensions are 96.2 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.355 kg. Main circuit terminals are IP20. Mechanical durability is 10,000,000 cycles. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VBC7-30-10-F-01
The ABB VBC7-30-10-F-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to UL/CSA and 600 V. Rated operational power in AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V, 5.5 kW at 500 V, and 3 kW at 690 V. The coil operates at 24 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.