- OS125GBS30K
ABB OS125GBS30K fuse protector, manufacturer ID 1SCA116400R1001. Three-pole, side-operated fuse switch disconnector with direct-mounted handle included, base mounting, and lug terminals of 20 mm width. Rated current is 125 A in the main circuit; conventional free-air thermal current is 125 A at 40 °C, and conventional thermal current is 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and pollution degree 3. Rated conditional short-circuit current is 80 kA at 690 V; rated short-time withstand current is 5 kA rms for 1 s. Fuse system is British Standard, fuse size A2-A4. Power loss is 4 W per pole at rated operating conditions. Tightening torque is 15 to 22 N·m. Standards: IEC 60947-3. Dimensions: 202 mm width, 140 mm height, 115 mm depth; net weight 2.115 kg.
- OS125GBS40N1K
ABB OS125GBS40N1K fuse switch disconnector, four-pole, side-operated, base mounting. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse size A2-A4, British Standard fuse system. Fourth pole left side, switched with solid link. Lug terminals, 20 mm width, tightening torque 15 to 22 N·m. Pollution degree 3. Dimensions 237 mm width, 140 mm height, 115 mm depth; net weight 2.615 kg. Standards: IEC 60947-3.
- OS125GBS40N2
The ABB OS125GBS40N2 is a four-pole fuse protector with a rated current of 125 A in the main circuit. It uses a British Standard fuse system for A2-A4 fuse sizes and is base mounted with side operation. Line terminals accept top-in/bottom-out or bottom-in/top-out connection. The fourth pole is switched with a solid link and positioned on the right side. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Conventional free-air thermal current is 125 A at 40 °C. Rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 217 mm wide, 140 mm high, and 127 mm deep; net weight is 2.56 kg. Handle and shaft are not included.
- OS125GD01
The ABB OS125GD01 is a front-operated, single-pole fuse switch disconnector for base mounting. It accepts NH000 and NH00 DIN fuse links. Rated current is 125 A in the main circuit; conventional free-air thermal current Ith is 125 A at 40 °C, and conventional thermal current Ithe is 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage Ui is 1000 V, and rated impulse withstand voltage Uimp is 8 kV. Rated conditional short-circuit current Inc is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. Dimensions are 77 mm wide, 140 mm high, and 130 mm deep; net weight is 0.9 kg. Terminals are lug type, 20 mm wide, tightened to 15 to 22 N·m. Handle and shaft are not included. Standard: IEC 60947-3.
- OS125GD02
ABB OS125GD02 fuse switch disconnector, manufacturer ID 1SCA116873R1001. Two-pole, front-operated, base-mounting unit for NH000/NH00 DIN fuses, with lug terminals 20 mm wide and tightening torque 15 to 22 N·m. Rated current 125 A; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220 to 240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, 110 kW at 690 V. Pollution degree 3. Power loss 4 W per pole at rated operating conditions. Dimensions 112 x 140 x 130 mm; net weight 1.325 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS125GD03
ABB OS125GD03 fuse protector, manufacturer ID 1SCA115638R1001. Three-pole fusible disconnect switch for base mounting, front operated, with switch mechanism 03 on the left side. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000 and NH00 DIN fuses. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Dimensions 146.5 x 140 x 130 mm; net weight 1.845 kg. Handle and shaft not included.
- OS125GD03BB
The ABB OS125GD03BB is a front-operated, 3-pole fuse switch disconnector for base mounting. It accepts NH000 and NH00 fuses in a DIN fuse system and uses lug terminals with a terminal width of 20 mm; tightening torque is 15 to 22 N·m. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and rated conditional short-circuit current 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 180 mm wide, 120 mm high, and 140 mm deep; net weight is 2.2 kg. A handle and shaft are not included.
- OS125GD03N3
ABB fuse protector, model OS125GD03N3, manufacturer ID 1SCA120287R1001. Three-pole, front-operated fuse switch disconnector for DIN NH000/NH00 fuses, base mounting with lug terminals 20 mm wide and tightening torque 15 to 22 N·m. Rated current 125 A; conventional free-air thermal current 125 A at 40 °C; fully enclosed thermal current 125 A. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Detachable neutral link integrated into the mechanism. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 138.5 mm width, 193 mm height, 131 mm depth; net weight 1.95 kg.