- OS125GD01
The ABB OS125GD01 is a front-operated, single-pole fuse switch disconnector for base mounting. It accepts NH000 and NH00 DIN fuse links. Rated current is 125 A in the main circuit; conventional free-air thermal current Ith is 125 A at 40 °C, and conventional thermal current Ithe is 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage Ui is 1000 V, and rated impulse withstand voltage Uimp is 8 kV. Rated conditional short-circuit current Inc is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. Dimensions are 77 mm wide, 140 mm high, and 130 mm deep; net weight is 0.9 kg. Terminals are lug type, 20 mm wide, tightened to 15 to 22 N·m. Handle and shaft are not included. Standard: IEC 60947-3.
- OS125GD02
ABB OS125GD02 fuse switch disconnector, manufacturer ID 1SCA116873R1001. Two-pole, front-operated, base-mounting unit for NH000/NH00 DIN fuses, with lug terminals 20 mm wide and tightening torque 15 to 22 N·m. Rated current 125 A; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220 to 240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, 110 kW at 690 V. Pollution degree 3. Power loss 4 W per pole at rated operating conditions. Dimensions 112 x 140 x 130 mm; net weight 1.325 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS125GD03
ABB OS125GD03 fuse protector, manufacturer ID 1SCA115638R1001. Three-pole fusible disconnect switch for base mounting, front operated, with switch mechanism 03 on the left side. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000 and NH00 DIN fuses. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Dimensions 146.5 x 140 x 130 mm; net weight 1.845 kg. Handle and shaft not included.
- OS125GD03BB
The ABB OS125GD03BB is a front-operated, 3-pole fuse switch disconnector for base mounting. It accepts NH000 and NH00 fuses in a DIN fuse system and uses lug terminals with a terminal width of 20 mm; tightening torque is 15 to 22 N·m. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and rated conditional short-circuit current 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 180 mm wide, 120 mm high, and 140 mm deep; net weight is 2.2 kg. A handle and shaft are not included.
- OS125GD03N3
ABB fuse protector, model OS125GD03N3, manufacturer ID 1SCA120287R1001. Three-pole, front-operated fuse switch disconnector for DIN NH000/NH00 fuses, base mounting with lug terminals 20 mm wide and tightening torque 15 to 22 N·m. Rated current 125 A; conventional free-air thermal current 125 A at 40 °C; fully enclosed thermal current 125 A. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Detachable neutral link integrated into the mechanism. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 138.5 mm width, 193 mm height, 131 mm depth; net weight 1.95 kg.
- OS125GD03N3P
ABB fuse switch disconnector, model OS125GD03N3P, manufacturer ID 1SCA120288R1001. Three-pole, front-operated device with a detachable neutral link integrated into the mechanism. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000/NH00 DIN fuses. Lug terminals, 20 mm wide, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Pistol handle and shaft included. Base mounting. Dimensions 138.5 mm wide, 193 mm high, 131 mm deep; 2.2 kg. Conforms to IEC 60947-3.
- OS125GD03P13
ABB OS125GD03P13 fuse protector, 3-pole, front-operated, base mounting. Rated operational voltage 690 V AC; rated current 125 A; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current fully enclosed 125 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000 and NH00 DIN fuse sizes. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Handle and shaft included. Dimensions 146.5 mm width, 140 mm height, 130 mm depth; net weight 2.035 kg. Conforms to IEC 60947-3.
- OS125GD04BBN2
ABB OS125GD04BBN2 is a four-pole fuse switch disconnector for DIN NH000/NH00 fuses, rated 125 A at 690 V AC. It is front-operated with base mounting, back-in/back-out line terminals, and lug terminals of 20 mm width. The fourth pole is switched with a solid link and positioned on the right side. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 80 kA at 690 V. Conventional free-air thermal current is 125 A at 40 °C; enclosed thermal current is 125 A. Power loss is 4 W per pole at rated operating conditions. Short-time withstand current is 5 kA rms for 1 s. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions: 215 mm width, 120 mm height, 140 mm depth; net weight 2.5 kg.