- OS125GD03BB
The ABB OS125GD03BB is a front-operated, 3-pole fuse switch disconnector for base mounting. It accepts NH000 and NH00 fuses in a DIN fuse system and uses lug terminals with a terminal width of 20 mm; tightening torque is 15 to 22 N·m. Rated current is 125 A in the main circuit, with conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and rated conditional short-circuit current 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 180 mm wide, 120 mm high, and 140 mm deep; net weight is 2.2 kg. A handle and shaft are not included.
- OS125GD03N3
ABB fuse protector, model OS125GD03N3, manufacturer ID 1SCA120287R1001. Three-pole, front-operated fuse switch disconnector for DIN NH000/NH00 fuses, base mounting with lug terminals 20 mm wide and tightening torque 15 to 22 N·m. Rated current 125 A; conventional free-air thermal current 125 A at 40 °C; fully enclosed thermal current 125 A. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Detachable neutral link integrated into the mechanism. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 138.5 mm width, 193 mm height, 131 mm depth; net weight 1.95 kg.
- OS125GD03N3P
ABB fuse switch disconnector, model OS125GD03N3P, manufacturer ID 1SCA120288R1001. Three-pole, front-operated device with a detachable neutral link integrated into the mechanism. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000/NH00 DIN fuses. Lug terminals, 20 mm wide, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Pistol handle and shaft included. Base mounting. Dimensions 138.5 mm wide, 193 mm high, 131 mm deep; 2.2 kg. Conforms to IEC 60947-3.
- OS125GD03P13
ABB OS125GD03P13 fuse protector, 3-pole, front-operated, base mounting. Rated operational voltage 690 V AC; rated current 125 A; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current fully enclosed 125 A. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Accepts NH000 and NH00 DIN fuse sizes. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Handle and shaft included. Dimensions 146.5 mm width, 140 mm height, 130 mm depth; net weight 2.035 kg. Conforms to IEC 60947-3.
- OS125GD04BBN2
ABB OS125GD04BBN2 is a four-pole fuse switch disconnector for DIN NH000/NH00 fuses, rated 125 A at 690 V AC. It is front-operated with base mounting, back-in/back-out line terminals, and lug terminals of 20 mm width. The fourth pole is switched with a solid link and positioned on the right side. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 80 kA at 690 V. Conventional free-air thermal current is 125 A at 40 °C; enclosed thermal current is 125 A. Power loss is 4 W per pole at rated operating conditions. Short-time withstand current is 5 kA rms for 1 s. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions: 215 mm width, 120 mm height, 140 mm depth; net weight 2.5 kg.
- OS125GD04BBN2P
The ABB OS125GD04BBN2P is a four-pole fuse switch disconnector for DIN NH000/NH00 fuses, rated 125 A in the main circuit and 690 V AC. It is front operated with a pistol handle and shaft included, base mounting, back-in/back-out line terminals, and lug terminals 20 mm wide with a tightening torque of 15 to 22 N·m. The fourth pole is on the right side, switched with a solid link. Ratings include 1000 V insulation voltage, 8 kV impulse withstand, 80 kA conditional short-circuit current at 690 V, and 5 kA rms short-time withstand current for 1 s. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Dimensions are 215 mm wide, 120 mm high, and 140 mm deep; net weight 2.7 kg.
- OS125GD04F
ABB OS125GD04F fuse protector, four-pole, front-operated, base mounting. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse system DIN, fuse size NH000/NH00. Fourth pole switched-fusible. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Degree of protection IP20 according to IEC 60529; pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 182 mm wide, 112 mm high, 130 mm deep; net weight 2.4 kg.
- OS125GD04FK
ABB fuse switch disconnector, model OS125GD04FK, four-pole, front-operated, base mounting with direct-mounted handle included. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse size NH000/NH00, DIN fuse system. Lug terminals, 20 mm terminal width, tightening torque 15 to 22 N·m. Pollution degree 3. Dimensions 182 mm wide, 112 mm high, 165 mm deep; net weight 2.44 kg. Standards: IEC 60947-3.