- OS63GD10
The ABB OS63GD10 is a single-pole fuse protector for DIN NH000 fuse systems, rated 63 A in the main circuit and 690 V AC. It is front operated with base mounting and screw terminals. Conventional free-air thermal current is 63 A at 40 °C; conventional thermal current fully enclosed is 63 A. Rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 2.5 kA rms for 1 s. Cable cross-section is 2.5 to 25 mm² for stranded and flexible conductors. Dimensions are 121 mm wide, 66 mm high and 112 mm deep; net weight 0.5 kg. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included.
- OS63GD11K
The ABB OS63GD11K is a two-pole fuse protector for DIN NH000 fuses, front operated and base mounted. It measures 165 mm wide, 91 mm high, and 112 mm deep, and weighs 0.88 kg. Connecting capacity is 2.5 to 25 mm² for stranded and flexible conductors. Power loss is 4 W per pole at rated operating conditions. The main circuit rated operational voltage is 690 V AC.
- OS63GD12/B162
ABB fuse protector, model OS63GD12/B162, manufacturer ID 1SCA156572R1001. This is a 3-pole fuse switch disconnector for base mounting, front operated, with screw terminals. It accepts NH000 DIN system fuses. Rated operational voltage of the main circuit is 690 V AC. Connecting capacity is stranded 2.5 to 25 mm² and flexible 2.5 to 25 mm². Power loss at rated operating conditions is 4 W per pole. Tightening torque is 3 N·m to 4 N·m. It is designed to IEC 60947-3. Product net weight is 160 kg. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS63GD13N1
ABB OS63GD13N1 fuse protector, order code 1SCA149787R1001. Four-pole front-operated fuse switch disconnector for NH000 DIN fuses, base mounting. Main circuit rated operational voltage 690 V AC. Screw terminals accept stranded and flexible conductors from 2.5 to 25 mm²; tightening torque 3 N·m to 4 N·m; main circuit wire stripping length 12 mm (0.47 in). Power loss at rated operating conditions is 4 W per pole. Dimensions are 121 mm wide, 138 mm high, and 112 mm deep; net weight 1.2 kg. Conforms to IEC 60947-3. Classified as ETIM EC001040 fuse switch disconnector.
- OS63GD13N2
ABB fuse protector, model OS63GD13N2, manufacturer ID 1SCA123065R1001. Four-pole, front-operated fuse switch disconnector for base mounting, using NH000 DIN fuse system. Rated operational voltage of the main circuit is 690 V AC, with power loss of 4 W per pole at rated operating conditions. Screw terminals accept stranded and flexible conductors from 2.5 to 25 mm²; tightening torque is 3 N·m to 4 N·m and main circuit wire stripping length is 12 mm (0.47 in). Dimensions are 121 mm wide, 138 mm high, and 112 mm deep; net weight 1.2 kg. Conforms to IEC 60947-3. ETIM 8 and ETIM 9 classification EC001040, fuse switch disconnector.
- OS63GD13N2P
The ABB OS63GD13N2P is a 4-pole fuse switch disconnector for base mounting, front operated, with the fourth pole on the right side, switched with a solid link. It accepts NH000 DIN fuses and screw terminals for stranded or flexible cable of 2.5 to 25 mm², with a 12 mm stripping length and tightening torque of 3 N·m or 4 N·m. Rated current is 63 A in the main circuit; rated operational voltage is 690 V AC. Conventional free-air thermal current is 63 A at 40 °C, and enclosed thermal current is 63 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current at 690 V is 80 kA. It conforms to IEC 60947-3. Dimensions are 121 mm wide, 138 mm high, and 112 mm deep; net weight 1.4 kg.
- OS63GD22F
The ABB OS63GD22F is a front-operated, 4-pole fuse switch disconnector for base mounting, with a switched-fusible fourth pole. It accepts NH000 DIN fuses and screw terminals for stranded or flexible cable from 2.5 to 25 mm². Rated current is 63 A in the main circuit; conventional free-air thermal current is 63 A at 40 °C, and fully enclosed thermal current is 63 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS63GD22FP
The ABB OS63GD22FP is a 4-pole front-operated fuse switch disconnector for base mounting, with a pistol handle and shaft included. It uses NH000 fuses in the DIN fuse system, and the fourth pole is a switched, fusible pole. Main circuit rated current is 63 A at a rated operational voltage of 690 V AC; conventional free-air thermal current is 63 A at 40 °C. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Screw terminals accept 2.5 to 25 mm² cable, with 12 mm stripping length and 3 to 4 N·m tightening torque. Dimensions are 136 mm wide, 125 mm high, and 121 mm deep; net weight is 1.39 kg.