- OS63GD13N1
ABB OS63GD13N1 fuse protector, order code 1SCA149787R1001. Four-pole front-operated fuse switch disconnector for NH000 DIN fuses, base mounting. Main circuit rated operational voltage 690 V AC. Screw terminals accept stranded and flexible conductors from 2.5 to 25 mm²; tightening torque 3 N·m to 4 N·m; main circuit wire stripping length 12 mm (0.47 in). Power loss at rated operating conditions is 4 W per pole. Dimensions are 121 mm wide, 138 mm high, and 112 mm deep; net weight 1.2 kg. Conforms to IEC 60947-3. Classified as ETIM EC001040 fuse switch disconnector.
- OS63GD13N2
ABB fuse protector, model OS63GD13N2, manufacturer ID 1SCA123065R1001. Four-pole, front-operated fuse switch disconnector for base mounting, using NH000 DIN fuse system. Rated operational voltage of the main circuit is 690 V AC, with power loss of 4 W per pole at rated operating conditions. Screw terminals accept stranded and flexible conductors from 2.5 to 25 mm²; tightening torque is 3 N·m to 4 N·m and main circuit wire stripping length is 12 mm (0.47 in). Dimensions are 121 mm wide, 138 mm high, and 112 mm deep; net weight 1.2 kg. Conforms to IEC 60947-3. ETIM 8 and ETIM 9 classification EC001040, fuse switch disconnector.
- OS63GD13N2P
The ABB OS63GD13N2P is a 4-pole fuse switch disconnector for base mounting, front operated, with the fourth pole on the right side, switched with a solid link. It accepts NH000 DIN fuses and screw terminals for stranded or flexible cable of 2.5 to 25 mm², with a 12 mm stripping length and tightening torque of 3 N·m or 4 N·m. Rated current is 63 A in the main circuit; rated operational voltage is 690 V AC. Conventional free-air thermal current is 63 A at 40 °C, and enclosed thermal current is 63 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current at 690 V is 80 kA. It conforms to IEC 60947-3. Dimensions are 121 mm wide, 138 mm high, and 112 mm deep; net weight 1.4 kg.
- OS63GD22F
The ABB OS63GD22F is a front-operated, 4-pole fuse switch disconnector for base mounting, with a switched-fusible fourth pole. It accepts NH000 DIN fuses and screw terminals for stranded or flexible cable from 2.5 to 25 mm². Rated current is 63 A in the main circuit; conventional free-air thermal current is 63 A at 40 °C, and fully enclosed thermal current is 63 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS63GD22FP
The ABB OS63GD22FP is a 4-pole front-operated fuse switch disconnector for base mounting, with a pistol handle and shaft included. It uses NH000 fuses in the DIN fuse system, and the fourth pole is a switched, fusible pole. Main circuit rated current is 63 A at a rated operational voltage of 690 V AC; conventional free-air thermal current is 63 A at 40 °C. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Screw terminals accept 2.5 to 25 mm² cable, with 12 mm stripping length and 3 to 4 N·m tightening torque. Dimensions are 136 mm wide, 125 mm high, and 121 mm deep; net weight is 1.39 kg.
- OS63GD22N1P
ABB OS63GD22N1P fuse protector, 4-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 63 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 63 A at 40 °C; conventional thermal current 63 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 2.5 kA rms for 1 s. AC-23A rated operational power: 18.5 kW at 220–240 V, 30 kW at 400 V and 415 V, 37 kW at 500 V, 55 kW at 690 V. NH000 DIN fuse system. Fourth pole left side, switched with solid link. Screw terminals, 2.5–25 mm², tightening torque 3 N·m or 4 N·m, stripping length 12 mm. Pollution degree 3. Standards: IEC 60947-3. Net 138 x 112 x 121 mm, 1.4 kg.
- OS63GD22N2P/B20
The ABB OS63GD22N2P/B20 is a four-pole fuse protector with base mounting and front operation. It accepts NH000 fuses in the DIN fuse system and uses screw terminals with a connecting capacity of 2.5 to 25 mm² for both stranded and flexible conductors. Tightening torque is 3 N·m to 4 N·m. The main circuit is rated 690 V AC, and power loss is 4 W per pole at rated operating conditions. The device is manufactured to IEC 60947-3. Manufacturer ID: 1SCA123220R1001. Net weight is 27.4 kg. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS63GD30
The ABB OS63GD30 is a front-operated, 3-pole fuse protector for base mounting, using NH000 DIN fuse systems. It is rated 63 A in the main circuit, with a rated operational voltage of 690 V AC and a rated insulation voltage of 1000 V. Conventional free-air thermal current is 63 A at 40 °C; fully enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated impulse withstand voltage is 12 kV. It accepts stranded or flexible cable from 2.5 to 25 mm² via screw terminals, with 12 mm wire stripping length and 3 N·m to 4 N·m tightening torque. Pollution degree is 3. Dimensions are 115 mm wide, 112 mm high, and 121 mm deep; net weight is 0.99 kg. Handle and shaft are not included. Standard: IEC 60947-3.