- OS63GD22F
The ABB OS63GD22F is a front-operated, 4-pole fuse switch disconnector for base mounting, with a switched-fusible fourth pole. It accepts NH000 DIN fuses and screw terminals for stranded or flexible cable from 2.5 to 25 mm². Rated current is 63 A in the main circuit; conventional free-air thermal current is 63 A at 40 °C, and fully enclosed thermal current is 63 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V. Power loss is 4 W per pole at rated operating conditions. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS63GD22FP
The ABB OS63GD22FP is a 4-pole front-operated fuse switch disconnector for base mounting, with a pistol handle and shaft included. It uses NH000 fuses in the DIN fuse system, and the fourth pole is a switched, fusible pole. Main circuit rated current is 63 A at a rated operational voltage of 690 V AC; conventional free-air thermal current is 63 A at 40 °C. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Screw terminals accept 2.5 to 25 mm² cable, with 12 mm stripping length and 3 to 4 N·m tightening torque. Dimensions are 136 mm wide, 125 mm high, and 121 mm deep; net weight is 1.39 kg.
- OS63GD22N1P
ABB OS63GD22N1P fuse protector, 4-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 63 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 63 A at 40 °C; conventional thermal current 63 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 2.5 kA rms for 1 s. AC-23A rated operational power: 18.5 kW at 220–240 V, 30 kW at 400 V and 415 V, 37 kW at 500 V, 55 kW at 690 V. NH000 DIN fuse system. Fourth pole left side, switched with solid link. Screw terminals, 2.5–25 mm², tightening torque 3 N·m or 4 N·m, stripping length 12 mm. Pollution degree 3. Standards: IEC 60947-3. Net 138 x 112 x 121 mm, 1.4 kg.
- OS63GD22N2P/B20
The ABB OS63GD22N2P/B20 is a four-pole fuse protector with base mounting and front operation. It accepts NH000 fuses in the DIN fuse system and uses screw terminals with a connecting capacity of 2.5 to 25 mm² for both stranded and flexible conductors. Tightening torque is 3 N·m to 4 N·m. The main circuit is rated 690 V AC, and power loss is 4 W per pole at rated operating conditions. The device is manufactured to IEC 60947-3. Manufacturer ID: 1SCA123220R1001. Net weight is 27.4 kg. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector.
- OS63GD30
The ABB OS63GD30 is a front-operated, 3-pole fuse protector for base mounting, using NH000 DIN fuse systems. It is rated 63 A in the main circuit, with a rated operational voltage of 690 V AC and a rated insulation voltage of 1000 V. Conventional free-air thermal current is 63 A at 40 °C; fully enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated impulse withstand voltage is 12 kV. It accepts stranded or flexible cable from 2.5 to 25 mm² via screw terminals, with 12 mm wire stripping length and 3 N·m to 4 N·m tightening torque. Pollution degree is 3. Dimensions are 115 mm wide, 112 mm high, and 121 mm deep; net weight is 0.99 kg. Handle and shaft are not included. Standard: IEC 60947-3.
- OS63GD30P
The ABB OS63GD30P is a front-operated, 3-pole fuse switch disconnector for base mounting, with NH000 fuses in a DIN fuse system. It is rated 63 A and 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 63 A at 40 °C; enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 2.5 kA rms for 1 s. AC-23A operational power is 30 kW at 400 V and 55 kW at 690 V. It uses screw terminals for 2.5 to 25 mm² cable, accepts stranded or flexible conductors, and complies with IEC 60947-3. Dimensions are 112 mm wide, 125 mm high, and 121 mm deep; weight is 1.2 kg.
- OS63GD40N1
ABB fuse protector, display model OS63GD40N1. Four-pole front-operated fuse switch disconnector for base mounting, with fuse size NH000 in the DIN fuse system. Rated current 63 A in the main circuit; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Conventional free-air thermal current 63 A at 40 °C; conventional thermal current 63 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 2.5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Cable cross-section 2.5 to 25 mm², screw terminals, tightening torque 3 N·m to 4 N·m, wire stripping length 12 mm. Dimensions 139 mm wide, 112 mm high, 121 mm deep; net weight 1.18 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS63GD40N2
ABB OS63GD40N2 is a four-pole fuse switch disconnector for NH000 DIN fuses, front operated and base mounted. The main circuit is rated 63 A at 690 V AC, with rated insulation voltage 1000 V and rated impulse withstand voltage 12 kV. Conventional free-air thermal current is 63 A at 40 °C; fully enclosed thermal current is 63 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 2.5 kA rms for 1 s. Screw terminals accept stranded or flexible cable from 2.5 to 25 mm², with 12 mm stripping length and 3 to 4 N·m tightening torque. Dimensions are 121 mm wide, 136 mm high, and 112 mm deep; net weight 1.2 kg. Standards: IEC 60947-3. Handle and shaft are not included.