- OS125GB22LR
The ABB OS125GB22LR is a four-pole fuse switch disconnector for base mounting, front operated, with line terminals left in and right out. It is rated 125 A (main circuit) at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 125 A at 40 °C; enclosed thermal current is 125 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 5 kA rms for 1 s. Fuse size is A2-A4 in the British Standard system; the fourth pole is switched-fusible. Power loss is 12 W per pole at rated operating conditions. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions: 141 mm wide, 277 mm high, 150 mm deep; 2.9 kg.
- OS125GB22LRP
ABB OS125GB22LRP fuse switch disconnector, four-pole, front-operated, base mounting, with pistol handle and shaft included. Rated current 125 A in the main circuit; conventional free-air thermal current 125 A at 40 °C and conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Rated operational power AC-23A: 37 kW at 220–240 V, 55 kW at 400 V and 415 V, 75 kW at 500 V, 110 kW at 690 V. Fuse size A2–A4, British Standard fuse system. Lug terminals, 20 mm wide, tightening torque 15 to 22 N·m. Pollution degree 3. Standards: IEC 60947-3. Dimensions 277 mm × 150 mm × 141 mm; net weight 3.1 kg.
- OS125GB22N1
ABB OS125GB22N1 fuse switch disconnector, 4-pole, rated current 125 A in the main circuit. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 5 kA rms for 1 s. Fuse size A2-A4, British Standard fuse system. Fourth pole is switched with solid link, left side. Front-operated, base mounting, lug terminals 20 mm wide, tightening torque 15 to 22 N·m. Power loss 4 W per pole at rated operating conditions. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft not included. Dimensions 192 mm width, 146 mm height, 192 mm depth; net weight 2.42 kg.
- OS125GB22N1P
The ABB OS125GB22N1P is a four-pole fuse switch disconnector for base mounting with front operation. It is rated 125 A at 690 V AC, with rated insulation voltage 1000 V and rated impulse withstand voltage 8 kV. Conventional free-air thermal current is 125 A at 40 °C; enclosed thermal current is 125 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 5 kA rms for 1 s. It accepts A2–A4 British Standard fuses. The fourth pole is on the left side, switched with a solid link. Power loss is 4 W per pole at rated operating conditions. Dimensions are 182 mm wide, 140 mm high, and 115 mm deep; net weight is 2.61 kg. It conforms to IEC 60947-3.
- OS125GBS30
The ABB OS125GBS30 is a three-pole fuse switch disconnector for base mounting with side operation. It is rated 125 A in the main circuit, with a conventional free-air thermal current of 125 A at 40 °C and a fully enclosed conventional thermal current of 125 A. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 5 kA rms for 1 s. It accepts British Standard fuses in sizes A2 to A4 and uses lug terminals 20 mm wide, tightened to 15 to 22 N·m. Dimensions are 182 mm wide, 140 mm high, and 115 mm deep; net weight is 2.06 kg. It conforms to IEC 60947-3. Handle and shaft are not included.
- OS125GBS30K
ABB OS125GBS30K fuse protector, manufacturer ID 1SCA116400R1001. Three-pole, side-operated fuse switch disconnector with direct-mounted handle included, base mounting, and lug terminals of 20 mm width. Rated current is 125 A in the main circuit; conventional free-air thermal current is 125 A at 40 °C, and conventional thermal current is 125 A fully enclosed. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and pollution degree 3. Rated conditional short-circuit current is 80 kA at 690 V; rated short-time withstand current is 5 kA rms for 1 s. Fuse system is British Standard, fuse size A2-A4. Power loss is 4 W per pole at rated operating conditions. Tightening torque is 15 to 22 N·m. Standards: IEC 60947-3. Dimensions: 202 mm width, 140 mm height, 115 mm depth; net weight 2.115 kg.
- OS125GBS40N1K
ABB OS125GBS40N1K fuse switch disconnector, four-pole, side-operated, base mounting. Rated current 125 A; rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 8 kV. Conventional free-air thermal current 125 A at 40 °C; conventional thermal current 125 A fully enclosed. Rated conditional short-circuit current 80 kA at 690 V. Rated short-time withstand current 5 kA rms for 1 s. Power loss 4 W per pole at rated operating conditions. Fuse size A2-A4, British Standard fuse system. Fourth pole left side, switched with solid link. Lug terminals, 20 mm width, tightening torque 15 to 22 N·m. Pollution degree 3. Dimensions 237 mm width, 140 mm height, 115 mm depth; net weight 2.615 kg. Standards: IEC 60947-3.
- OS125GBS40N2
The ABB OS125GBS40N2 is a four-pole fuse protector with a rated current of 125 A in the main circuit. It uses a British Standard fuse system for A2-A4 fuse sizes and is base mounted with side operation. Line terminals accept top-in/bottom-out or bottom-in/top-out connection. The fourth pole is switched with a solid link and positioned on the right side. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 8 kV. Conventional free-air thermal current is 125 A at 40 °C. Rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Dimensions are 217 mm wide, 140 mm high, and 127 mm deep; net weight is 2.56 kg. Handle and shaft are not included.