- OS800D12K
ABB OS800D12K fuse protector, 3-pole, front-operated, base mounting, with direct-mounted handle included. Rated current 800 A in the main circuit; rated operational voltage 690 V AC. Conventional free-air thermal current 800 A at 40 °C; conventional thermal current 720 A fully enclosed. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, rated conditional short-circuit current 80 kA at 690 V, and rated short-time withstand current 18 kA rms for 1 s. Accepts NH3 DIN fuse system fuses. Cable cross-section 2.5 to 25 mm²; lug terminals 39 mm wide; tightening torque 50 to 75 N·m. Power loss 75 W per pole at rated operating conditions. Pollution degree 3. Dimensions 343 mm wide, 306 mm high, 233 mm deep; net weight 13 kg. Standards: IEC 60947-3.
- OS800D13F
The ABB OS800D13F is a four-pole fuse protector with base mounting, front operation, and lug terminals. It is rated 800 A in the main circuit, with conventional free-air thermal current 800 A at 40 °C and conventional thermal current 720 A fully enclosed. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Fuse size is NH3, DIN system, with a switched fusible fourth pole. Power loss is 75 W per pole at rated operating conditions. Terminal width is 39 mm and tightening torque is 50 to 75 N·m. Pollution degree is 3. Standards: IEC 60947-3. Handle and shaft are not included.
- OS800D13N2
ABB OS800D13N2 fuse protector, manufacturer ID 1SCA022834R4790. Four-pole, front-operated fuse switch disconnector for NH3 DIN fuses, base mounting, with the fourth pole on the right side, switched with solid link. Rated current 800 A; conventional free-air thermal current 800 A at 40 °C; conventional thermal current 720 A fully enclosed. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Dimensions 429 x 306 x 233 mm; net weight 18.54 kg. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Conforms to IEC 60947-3. Handle and shaft not included.
- OS800D13N2K
The ABB OS800D13N2K is a 4-pole fuse protector with a front-operated, base-mounted design and a direct-mounted handle. It uses NH3 fuses in the DIN fuse system, with the fourth pole on the right side, switched with a solid link. The main circuit is rated 800 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. It conforms to IEC 60947-3. Dimensions are 289 mm wide, 429 mm high, and 306 mm deep; net weight is 19.4 kg.
- OS800D13N2P
The ABB OS800D13N2P is a four-pole fuse protector with a main circuit rated current of 800 A and a rated operational voltage of 690 V AC. It uses NH3 DIN fuses and is front operated via a pistol handle and shaft, with base mounting. The fourth pole is switched with a solid link and positioned on the right side. Terminal type is lug terminals, 39 mm wide, with tightening torque of 50 to 75 N·m. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. It conforms to IEC 60947-3.
- OS800D20
The ABB OS800D20 is a 2-pole fuse switch disconnector with front operation and base mounting. It accepts NH2 and NH3 fuses in a DIN fuse system and uses lug terminals with a tightening torque of 50 to 75 N·m. The main circuit is rated 690 V AC, and power loss is 75 W per pole at rated operating conditions. Dimensions are 233 mm wide, 255 mm high, and 306 mm deep, with a net weight of 10.1 kg. The device is classified under IEC 60947-3. The manufacturer ID is 1SCA139869R1001. It falls under WEEE Category 5, small equipment with no external dimension more than 50 cm.
- OS800D21
ABB OS800D21 fuse switch disconnector, 3-pole, front-operated, base mounting. Rated current 800 A; conventional free-air thermal current 800 A at 40 °C; fully enclosed thermal current 720 A. Rated operational voltage 690 V AC. Rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, pollution degree 3. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Accepts NH3 DIN fuse system fuses. Lug terminals, 39 mm terminal width, tightening torque 50 to 75 N·m. Line terminals top in/bottom out or bottom in/top out. Power loss 75 W per pole at rated operating conditions. Standards: IEC 60947-3. Dimensions 341 mm width, 306 mm height, 233 mm depth; net weight 14.39 kg. Handle and shaft not included.
- OS800D22F
The ABB OS800D22F is a four-pole fuse protector with base mounting and front operation. It accepts NH3 fuses in the DIN system. The main circuit is rated 800 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed conventional thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 19.154 kg. Lug terminals are 39 mm wide, tightened to 50 to 75 N·m. Standards: IEC 60947-3. Handle and shaft are not included.