- OS800D22F
The ABB OS800D22F is a four-pole fuse protector with base mounting and front operation. It accepts NH3 fuses in the DIN system. The main circuit is rated 800 A at 690 V AC, with a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed conventional thermal current is 720 A. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 19.154 kg. Lug terminals are 39 mm wide, tightened to 50 to 75 N·m. Standards: IEC 60947-3. Handle and shaft are not included.
- OS800D22FP
The ABB OS800D22FP is a four-pole fuse protector with a switched-fusible fourth pole, base mounting, and front operation via an included pistol handle and shaft. It accepts NH3 DIN fuses and uses lug terminals 39 mm wide, tightened to 50 to 75 N·m. The main circuit is rated 800 A at 690 V AC, with conventional free-air thermal current 800 A at 40 °C and enclosed thermal current 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. It conforms to IEC 60947-3. Net dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight is 19.654 kg.
- OS800D22N1P
The ABB OS800D22N1P is a four-pole fuse switch disconnector with a switched fourth pole on the left side, fitted with a solid link. It uses NH3 DIN fuse links and accepts lug terminals 39 mm wide, tightened to 50 to 75 N·m. Rated current for the main circuit is 800 A; conventional free-air thermal current is 800 A at 40 °C, and fully enclosed conventional thermal current is 720 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, and rated impulse withstand voltage 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and short-time withstand current is 18 kA rms for 1 s. The device is front operated with a pistol handle and shaft included, base mounting, pollution degree 3, and conforms to IEC 60947-3.
- OS800D22N2-60
ABB fuse protector, model OS800D22N2-60, manufacturer ID 1SCA022864R9710. Four-pole, front-operated unit for base mounting with lug terminals. Accepts NH2 and NH3 fuse sizes in the DIN fuse system. Rated operational voltage of the main circuit is 690 V AC. Power loss is 75 W per pole at rated operating conditions. Terminal tightening torque is 50 to 75 N·m. The product weighs 15 kg and is classified under IEC 60947-3. ETIM 8 and ETIM 9 classification is EC001040, fuse switch disconnector. UNSPSC code 39122233; IDEA granular category code 5291, fuse switch disconnector. WEEE category 5, small equipment with no external dimension more than 50 cm.
- OS800D30
ABB OS800D30 is a 3-pole fuse switch disconnector for NH3 DIN fuses, base mounting, front operated with the operating mechanism at 30 (right side). It is rated 800 A in the main circuit and 720 A fully enclosed, with a conventional free-air thermal current Ith of 800 A at 40 °C. Rated operational voltage is 690 V AC; rated insulation voltage is 1000 V and rated impulse withstand voltage is 12 kV. Rated conditional short-circuit current is 80 kA at 690 V, and rated short-time withstand current Icw is 18 kA rms for 1 s. Power loss is 75 W per pole at rated operating conditions. Lug terminals are 39 mm wide, tightened to 50 to 75 N·m. Pollution degree 3. Standards: IEC 60947-3. Handle and shaft are not included. Dimensions: 343 mm width, 306 mm height, 233 mm depth; net weight 14.39 kg.
- OS800D30P
The ABB OS800D30P is a three-pole fuse protector with a rated current of 800 A in the main circuit and a rated operational voltage of 690 V AC. It is a front-operated, base-mounted device with lug terminals and a pistol handle and shaft included. Fuse size is NH3 in the DIN system. Conventional free-air thermal current is 800 A at 40 °C; fully enclosed conventional thermal current is 720 A. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated conditional short-circuit current is 80 kA at 690 V. It conforms to IEC 60947-3. Net dimensions are 343 mm wide, 306 mm high, and 233 mm deep, with a net weight of 14.89 kg.
- OS800D31F
ABB fuse protector, model OS800D31F, manufacturer ID 1SCA022834R6810. Four-pole front-operated fuse switch disconnector for base mounting, with switched-fusible fourth pole and NH3 DIN fuse system. Rated current 800 A; conventional free-air thermal current 800 A at 40 °C; fully enclosed thermal current 720 A. Rated operational voltage 690 V AC; rated insulation voltage 1000 V; rated impulse withstand voltage 12 kV. Rated conditional short-circuit current 80 kA at 690 V; rated short-time withstand current 18 kA rms for 1 s. Power loss 75 W per pole at rated operating conditions. Lug terminals, 39 mm wide, tightening torque 50 to 75 N·m. Pollution degree 3. Dimensions 429 x 306 x 233 mm; net weight 19.154 kg. Standards: IEC 60947-3. Handle and shaft not included.
- OS800D31N2
ABB OS800D31N2 fuse switch disconnector, 4-pole, front-operated, base mounting, with the fourth pole on the right side switched with a solid link. It accepts NH3 DIN fuses. Rated current is 800 A in the main circuit; conventional free-air thermal current is 800 A at 40 °C, and conventional thermal current fully enclosed is 720 A. Rated operational voltage is 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 12 kV, and rated conditional short-circuit current 80 kA at 690 V. Power loss is 75 W per pole at rated operating conditions. Dimensions are 429 mm wide, 306 mm high, and 233 mm deep; net weight 18.54 kg. Standards: IEC 60947-3. Handle and shaft are not included.